Related Experiment Video
Updated: Aug 5, 2025

Scanning Electron Microscopic Evaluation of Surface Defects of Remover Retreatment File After Single and Multiple Uses
Published on: October 11, 2024
Retrieval analysis of the Essure® micro insert female sterilization implant: Methods for metal ion and microscopic
Charley Goodwin1, Can Aslan1, Jeremy L Gilbert1
1Department of Bioengineering, 301 Rhodes Research Center, Clemson University, Clemson SC 29634-0905, United States; Clemson Medical University of South Carolina Bioengineering Program, 68 Presidents Street, Charleston, SC 29464, United States.
Abstract:
The Essure® Device is a female sterilization implant comprised of four alloys (Ni-Ti, 316L SS, Pt-Ir and Sn-Ag) and Dacron fibers. As part of the mandated 522 post-market surveillance study, implant retrieval and metal-ion analysis methods were developed separate from patient clinical data, to quantify trace metal ions found in tissue and to assess implant degradation present. Three segments of tissue (proximal implant, distal implant, and tissue distal from the implant) stored in neutral buffered formalin, were retrieved. Tissue was prepared for metal ion analysis using inductively coupled mass spectrometry (ICP-MS). Implant sections from four patients, were analyzed using digital optical microscopy (DOM), scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS). Image analysis showed Sn-Ag solder corroded and elevated Sn ion levels in tissue proximal to the solder compared to tissues more remote in all cases observed. The 316L SS exhibited signs of degradation with high surface concentrations of molybdenum and chromium and low iron compared to the parent alloy. Evidence of elevated iron, chromium and nickel within the tissues and storage solutions combined with precipitation of an iron-calcium-phosphorous material on some implants indicate evidence of SS corrosion. Ni-Ti, Pt-Ir and Dacron appear to have no major damage. This study includes preliminary results as part of the ongoing 522 study and therefore no final conclusions regarding the device or patient data can be drawn from this present study until the entire 522 study is complete. STATEMENT OF SIGNIFICANCE: The Essure Device is a female sterilization implant that was implanted into approximately 750,000 women. The device is composed of polyethylene terephthalate fibers and 4 metal alloys, 316L stainless steel, Nickel-Titanium, Tin-Silver and Platinum-Iridium. Following an increase in patient reported adverse events, the FDA required a 522-post market surveillance study. As part of this study, implants are retrieved from patients via salpingectomy or hysterectomy. This study focuses on the development of the implant retrieval methods following surgery, with focus on measuring local tissue metal ions, their distribution and assessing the degradation of the implant without correlation to patient clinical condition.
More Related Videos
05:54Stereo-Electro-Encephalo-Graphy SEEG With Robotic Assistance in the Presurgical Evaluation of Medical Refractory Epilepsy: A Technical Note
Published on: June 13, 2016
08:29Author Spotlight: Multiplex Immunohistochemistry for Understanding Immune Regulation by Uterine NK Cells in Pregnancy
Published on: October 25, 2024