Endoscopic ultrasound diagnosis system based on deep learning in images capture and segmentation training of solid
Anliu Tang1,2, Pan Gong1, Ning Fang1
1Department of Gastroenterology, The Third Xiangya Hospital of Central South University, Changsha, Hunan, China.
Background:
Early detection of solid pancreatic masses through contrast-enhanced harmonic endoscopic ultrasound (CH-EUS) is important. But CH-EUS is difficult to learn.
Purpose:
To design a deep learning-based CH-EUS diagnosis system (CH-EUS MASTER) for real-time capture and segmentation of solid pancreatic masses and to verify its value in the training of pancreatic mass identification under endoscopic ultrasound (EUS).
Methods:
We designed a real-time capture and segmentation model for solid pancreatic masses and then collected 4530 EUS images of pancreatic masses retrospectively, used for training and testing of this model at a ratio of 8:2. The model is loaded into the EUS host computer to establish the CH-EUS MASTER system. A crossover trial was then conducted to evaluate the model's value in EUS trainee training by successfully conducting two groups of EUS trainees in model learning and trainer-guided training. The intersection over union (IoU) and the time to find the lesion were used to evaluate the model performance metrics, and the Mann-Whitney test was used to compare the IoU and the time to find the lesion in different groups of subjects. Paired t-test was used to compare the effects before and after training. When α ≤ 0.05, it is considered to have a significant statistical difference.
Results:
The model test showed that the model successfully captured and segmented the pancreatic solid mass region in 906 EUS images. The real-time capture and segmentation model had a Dice coefficient of 0.763, a recall rate of 0.941, a precision rate of 0.642, and an accuracy of 0.842 (when the threshold is set to 0.5), and the median IoU of all cases was 0.731. For the AI training effect, the average IoU of eight trainees improved from 0.80 to 0.87 (95% CI, 0.032-0.096; p = 0.002). The average time for identifying lesions in the pancreatic body and tail improved from 22.75 to 17.98 s (95% CI, 3.664-5.886; p < 0.01). The average time for identifying lesions in the pancreatic head and uncinate process improved from 34.21 to 25.92 s (95% CI, 7.661-8.913; p < 0.01).
Conclusion:
CH-EUS MASTER can provide an effect equivalent to trainer guidance in training pancreatic solid mass identification and segmentation under EUS.
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...