Effect of iodine concentration and body size on iodine subtraction in virtual non-contrast imaging: A phantom study
T Shirasaka1, T Kojima2, S Yamane3
1Graduate School of Health Sciences, Kumamoto University, 4-24-1 Kuhonji, Kumamoto, 862-0976, Japan; Division of Radiology, Department of Medical Technology, Kyushu University Hospital, 3-1-1 Maidashi, Higashi Ward, Fukuoka, 812-8582, Japan.
Introduction:
Dual-energy computed tomography (DECT) can generate virtual non-contrast (VNC) images. Herein, we sought to improve the accuracy of VNC images by identifying the optimal slope of contrast media (SCM) for VNC-image generation based on the iodine concentration and subject's body size.
Methods:
We used DECT to scan a multi-energy phantom including four iodine concentration rods (15, 10, 5, and 2 mg/mL), and 240 VNC images (eight SCM ranging from 0.49 to 0.56 × three body sizes × ten scans) that were generated by three-material decomposition. The CT number of each iodine and solid water rod part was measured in each VNC image. The difference in the CT number between the iodine and the solid water rod part was calculated and compared using paired t-test or repeated measures ANOVA.
Results:
The SCM that achieved an absolute value of the difference in CT number of <5.0 Hounsfield units (HU) for all body sizes simultaneously was greater at lower iodine concentration (SCM of 0.5, 0.51, and 0.53 at 10, 5, and 2 mg/mL iodine, respectively). At an iodine concentration of 15 mg/mL, no SCM achieved an absolute difference of <5.0 HU in CT number for all body sizes simultaneously. At all iodine concentrations, the SCM achieving the minimal difference in the CT number increased with the increase in body size.
Conclusion:
By adjusting the SCM according to the iodine concentration and body size, it is possible to generate VNC images with an accuracy of <5.0 HU.
Implications For Practice:
Improving the accuracy of VNC images minimizing incomplete iodine subtraction would make it possible to replace true non-contrast (TNC) images with VNC images and reduce the radiation dose.
More Related Videos
11:05Tissue-simulating Phantoms for Assessing Potential Near-infrared Fluorescence Imaging Applications in Breast Cancer Surgery
Published on: September 19, 2014
07:26Synthesis of 68Ga Core-doped Iron Oxide Nanoparticles for Dual Positron Emission Tomography /T1Magnetic Resonance Imaging
Published on: November 20, 2018
Related Concept Videos
Radiological Investigation I: X-ray and CT
Redox Titration: Iodimetry and Iodometry
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies III: Computed Tomography