Determination of Clomipramine using eco-friendly solid-contact ionophore-doped potentiometric sensor
Adel M Michael1, Amr M Mahmoud2, Nesma M Fahmy1
1Pharmaceutical Chemistry Department, Faculty of Pharmacy, Ahram Canadian University, October city, Egypt.
Introduction:
Clomipramine is a tricyclic antidepressant acting as a serotonin reuptake inhibitor. Its maximum plasma concentration (Cmax) is 13-310 ng/mL, the therapeutic range is 220-500 ng/mL and its toxic effect appears in doses above 900 ng/mL.
Objectives:
The fabrication of eco-friendly solid-contact ion-selective electrodes to evaluate the concentration of Clomipramine in different matrices based on disposable screen-printed carbon electrode.
Methods:
Disposable screen-printed carbon electrode was utilized as a substrate to fabricate the proposed sensors. The sensors were optimized to determine Clomipramine using calix[4]arene as an ionophore into PVC polymeric membrane to enhance selectivity towards the target analyte. The solid-contact sensor potential stability was improved by the incorporation of graphene nanoparticles transducer layer.
Results:
The sensors were assessed as per the IUPAC recommendations. The linearity range was 1 × 10- 2 to 1 × 10- 5.3 M. The sensors were successfully applied to determine CLM in the pharmaceutical formulation. Furthermore, the ion selective electrodes were applied for Clompiramine assay in spiked plasma for the purpose of Point-of-Care testing to be a diagnostic tool for therapeutic monitoring of the cited central nervous system agent. The findings were statistically compared to the reported method showing no statistically significant difference.
Conclusion:
This work was concerned with developing a green analytical method for the determination of Clomipramine. The proposed SC-ISE was mixed with graphene nanocomposite transducer interlayer. The graphene layer succeeded in preventing the formation of an aqueous layer so resulted in a stable, reproducible standard potential besides the rapid response time.
More Related Videos
Related Concept Videos
Potentiometry: Membrane Electrodes
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Controlled-Potential Coulometry: Electrolytic Methods
The chosen potential...
Ion-Exchange Chromatography
Potentiometry: Overview
Potentiometric Titration: Overview