Related Experiment Video
Updated: Aug 5, 2025

Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
Closed reduction of dorsally displaced distal radius fractures in the elderly provided improved final radiographic
Sondre Stafsnes Hassellund1,2, Ingrid Oftebro3, John Haakon Williksen3
1Division of Orthopaedic Surgery, Oslo University Hospital, Oslo, Norway. Sondre.hassellund@gmail.com.
Background:
Recent guidelines recommend non-operative treatment as primary treatment in elderly patients with displaced distal radius fractures. Most of these fractures are closely reduced. We aimed to evaluate the radiological results of closed reduction and casting of dorsally displaced distal radius fractures in patients 65 years or older.
Methods:
A total of 290 patients treated during the years 2015, 2018 and 2019 in an urban outpatient fracture clinic with complete follow-up at least 5 weeks post-reduction were available for analysis. Closed fracture reduction was performed by manual traction under hematoma block. A circular plaster of Paris cast was used. Radiographs pre- and post-reduction and at final follow-up were analyzed.
Results:
Mean age was 77 years (SD 8) and 258 (89%) were women. Dorsal tilt improved from mean 111° (range 83-139) to 89° (71-116) post-reduction and fell back to mean 98° (range 64-131) at final follow-up. Ulnar variance was 2 mm ((-1)-12) pre-reduction, 0 mm ((-3)-5) post-reduction and ended at mean 2 mm (0-8). Radial inclination went from 17° ((-6)-30) to 23° (SD 7-33), and then back to 18° (0-32) at final follow-up. 41 (14%) patients had worse alignment at final follow-up compared to pre-reduction. 48 (17%) obtained a position similar to the starting point, while 201 (69%) improved. Fractures with the volar cortex aligned after reduction retained 0.4 mm (95% Confidence Interval (CI) 0.1 to 0.7; p = 0,022) more radius length during immobilization. In a regression analysis, less ulnar variance in initial radiographs (OR 1.8 (95% CI 1.4 to 2.3) per mm, p < 0.001) and lower age (OR 1.06 (95% CI 1.02 to 1.09) per year, p < 0.003) protected against loss of reduction.
Conclusion:
Subsequent loss of reduction after initial closed reduction was seen in most distal radius fractures. Reduction improved overall alignment in 2/3 of the patients at final follow-up. An aligned volar cortex seemed to protect partially against loss of radial length.
More Related Videos
04:42Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
07:35Creating Rigidly Stabilized Fractures for Assessing Intramembranous Ossification, Distraction Osteogenesis, or Healing of Critical Sized Defects
Published on: April 11, 2012
Related Concept Videos
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Bones of the Upper Limb: Radius
The radius has a nail-shaped head, and a...