Related Experiment Video
Updated: Aug 5, 2025

Probe-based Confocal Laser Endomicroscopy of the Urinary Tract: The Technique
Published on: January 10, 2013
Clinical Evaluation of Miniature Flexible Scope for Diagnosis of Ureteroscope Working Channel Defects
Tony T Chen1, Mimi V Nguyen2, Clara Cerrato1,3
1Department of Urology, University of California San Diego, San Diego, California, USA.
Abstract:
To evaluate flexible ureteroscope working channels with a 1.06 mm digital borescope (Clarus Medical, Minneapolis, MN) and identify factors contributing to ureteroscope damage over time. We performed a single institutional prospective study of patients undergoing stone surgery using a nondisposable flexible ureteroscope. A 1.06 mm borescope was used to evaluate ureteroscopes before and after surgery. Borescope videos were reviewed by two independent researchers to quantify average pre- and postprocedural damage. Twenty-five procedures were performed with pre- and postprocedural borescope assessment between August 2021 and February 2022. All patients received preoperative CT imaging depicting a mean axial stone size of 14.1 ± 8.4 mm and density of 923.4 ± 458.1 HU. Mean operative time was 63.8 ± 34.0 minutes. The average number an instrument passes through the working channel was 2.1 ± 1.6. Laser was used in 11 cases with mean laser time of 18.8 ± 19.7 minutes and mean total energy of 5.8 ± 4.2 KJ. On preoperative assessment, all ureteroscopes had some form of defect (24% shave, 32% pinhole, 96% dents and scratches, and 28% discolorations). During postoperative assessment, 23/25 (92%) ureteroscopes showed additional damage with an average of 3.7 ± 2.8 imperfections acquired after one use. Significant differences were seen in acquired shavings (p = 0.028) and scratches or dents (p = 0.018). Of the 355 imperfections seen on postoperative evaluation, 0.4% were shave, 3% were pinhole, 85.8% were dents and scratches, and 10.8% were discolorations. The Clarus borescope observed defects after the majority of flexible ureteroscopy procedures for nephrolithiasis. Although such disruptions may not immediately render ureteroscopes nonfunctional, they are more common than previously described and could increase maintenance costs. Further studies are needed to investigate the burden of unit damage per procedure to raise operator awareness and reduce preventable ureteroscope imperfections.
More Related Videos
Related Concept Videos
Urologic Endoscopic Procedure: Cystoscopic Examination
Imaging Studies V: Intravenous Urography and Retrograde Pyelography
Imaging Studies VI: Voiding Cystourethrography and Cystography
Imaging Studies II: Ultrasonography
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Imaging Studies I: Kidney, Ureter, and Bladder Studies

