Related Experiment Video
Updated: Aug 5, 2025

Author Spotlight: Improving Radiation Therapy Access with Radiation Planning Assistant
Published on: October 6, 2023
Systematic Review on Diagnostic Reference Levels for Computed Tomography Examinations in Radiation Therapy Planning
Shreekripa Rao1, Krishna Sharan2, Suresh Sukumar3
1Department of Radiotherapy and Oncology, Manipal College of Health Professions, Manipal 576104, Karnataka, India.
Abstract:
Background: In August 2017, the European Commission awarded the "European Study on Clinical Diagnostic Reference Levels (DRL) for X-ray Medical Imaging" project to the European Society of Radiology to provide up-to-date Diagnostic Reference Levels based on clinical indications. This work aimed to conduct an extensive literature review by analyzing the most recent studies published and the data provided by the National Competent Authorities to understand the current situation regarding Diagnostic Reference Levels based on clinical indications for Radiation Therapy Computed Tomography. Objective: To review the literature on established DRLs and methodologies for establishing Diagnostic reference levels in radiation therapy planning computed tomography (RTCT). Methods: Eligibility criteria: A cohort study (observational design) reporting DRLs in adult patients undergoing computed tomography (CT) for radiation therapy for the region head and neck or pelvis were included. The comprehensive literature searches for the relevant studies published between 2000 and 2021 were performed using PubMed, Scopus, CINHAL, Web of Science, and ProQuest. Results: Three hundred fifty-six articles were identified through an extensive literature search. Sixty-eight duplicate reports were removed. The title and abstract of 288 studies were assessed and excluded if they did not meet the inclusion criteria. Sixteen of 288 articles were selected for full-text screening (studies conducted between 2000 and 2021). Five articles were included in the review after the full-text screening. Conclusions: A globally approved standard protocol that includes scanning techniques, dose measurement method, and DRL percentile needs to be established to make a valuable and accurate comparison with international DRLs.
More Related Videos
08:25Radiation Planning Assistant - A Streamlined, Fully Automated Radiotherapy Treatment Planning System
Published on: April 11, 2018
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation I: X-ray and CT
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...