Related Experiment Video
Updated: Aug 5, 2025

Assessment of Respiratory Function in Conscious Mice by Double-chamber Plethysmography
Published on: July 10, 2018
New 6-Minute-Walking Test Parameter-Distance/Desaturation Index (DDI) Correctly Diagnoses Short-Term Response to
Katarzyna B Lewandowska1, Małgorzata Sobiecka1, Piotr W Boros2
11st Department of Lung Diseases, National Research Institute of Tuberculosis and Lung Diseases, 01-138 Warsaw, Poland.
Abstract:
The six-minute-walking test (6MWT) is an easy-to-perform, cheap and valuable tool to assess the physical performance of patients. It has been used as one of the endpoints in many clinical trials investigating treatment efficacy in pulmonary arterial hypertension and idiopathic pulmonary fibrosis. However, the utility of 6MWT in patients diagnosed with hypersensitivity pneumonitis (HP) is still under investigation. The aim of the present retrospective study was to assess the value of different 6MWT parameters, including the newly developed distance-desaturation index (DDI), to evaluate immunomodulatory treatment outcomes in HP patients.
Methods:
6MWT parameters (distance, initial saturation, final saturation, desaturation, distance-saturation product (DSP), and DDI) were analyzed at baseline and after 3 to 6 months of treatment with corticosteroids alone or in combination with azathioprine.
Results:
91 consecutive HP patients diagnosed and treated in a single pulmonary unit from 2005 to 2017 entered the study. There were 44 (48%) males and 52 (57%) patients with fibrotic HP (fHP). Sixty-three patients (69%) responded to treatment (responders) and 28 (31%) did not respond (non-responders). In the responders group, all parameters assessed during 6MWT significantly improved, whereas in non-responders, they worsened. Medians (95% CI) of best indices were post-treatment DDI/baseline DDI-1.67 (1.85-3.63) in responders versus 0.88 (0.7-1.73) in non-responders (p = 0.0001) and change in walking distance-51 m (36-72 m) in responders, versus 10.5 m (-61.2-27.9) in non-responders (p = 0.0056). The area under the curve (AUC) of receiver operating characteristics (ROC) for post-treatment DDI/baseline DDI was 0.74 and the optimal cut-off was 1.075, with 71% of specificity and 71% of sensitivity.
Conclusions:
6MWT may be used as a tool to assess and monitor the response to immunomodulatory therapy in HP patients, especially if indices incorporating both distance and desaturation are used. Based on the present study results, we recommend 6MWD and DDI use, in addition to FVC and TL,co, to monitor treatment efficacy in patients with interstitial lung diseases.
More Related Videos
Related Concept Videos
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...
Pulmonary Tuberculosis IV
Several diagnostic approaches are used to detect TB. The conventional method is the Tuberculin Skin Test (TST), also known as the Mantoux test. However, this method has...

