Related Experiment Video
Updated: Aug 5, 2025

Measuring Carbon-based Contaminant Mineralization Using Combined CO2 Flux and Radiocarbon Analyses
Published on: October 21, 2016
Radon at Kilbourne Hole Maar and Magnetic and Gravimetric Correlations
Michel E Luna-Lucero1, Laszlo Sajo-Bohus2, Jorge A Lopez1
1Department of Physics, University of Texas at El Paso, El Paso, TX 79968-0515, USA.
Abstract:
Soil radon gas concentrations ranging from the detection limit up to 15 kBq/m3 were measured for the first time at the Kilbourne Hole maar in two selected regions: the first region was located on the western volcanic field, and the second was located inside the crater, near the southern border. Radioactive anomalies were found in association with the pyroclastic deposit, and the corresponding heat map provided information on the radon diffusion direction by the CRn gradient. It was observed for the first time that the anomalies found at the southern border are associated with a known geological fault, in opposition to what was found on the western border. The results provided by a radon activity concentration gradient of above (8 kBq/m3)/15 m suggest the existence of a fault that has not been detected yet. The observation that high levels near a dormant fault are related to tectonically enhanced radon was confirmed. The activity concentrations of Rn-gas were contrasted to existing gravimetric and magnetic data to provide measuring information on radon emanation, suggesting the existence of a high, naturally occurring radioactivity in the soil in the first place or an increased porosity of the locally defined lithology. The results indicated a higher correlation of 85% with magnetic anomalies. This is in opposition to the gravimetric data, which was only 30%. This study is a contribution to the characterization maar of volcanic geology by the soil radon activity index, which was designated as "low" in this case.
More Related Videos
06:06Sediment Core Extrusion Method at Millimeter Resolution Using a Calibrated, Threaded-rod
Published on: August 17, 2016
12:18Co-localizing Kelvin Probe Force Microscopy with Other Microscopies and Spectroscopies: Selected Applications in Corrosion Characterization of Alloys
Published on: June 27, 2022
Related Concept Videos
Magnetic Susceptibility and Permeability
When diamagnetic materials are placed under an external magnetic field, the moments opposite to the field are induced. Hence, the susceptibility for diamagnets has a minimal negative value of 10-5–10-6. Since...
Resistivity
Magnetostatic Boundary Conditions
Atomic Nuclei: Magnetic Resonance
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...