Related Experiment Video
Updated: Aug 5, 2025

Transradial Access Chemoembolization for Hepatocellular Carcinoma Patients
Published on: September 20, 2020
Lower Patient Height and Weight Are Predisposing Factors for Complex Radial Arterial Catheterization.
Kristine Huber1, Jan Menzenbach1, Markus Velten1
1Department of Anesthesiology and Intensive Care Medicine, University Hospital Bonn, Venusberg-Campus 1, 53127 Bonn, Germany.
Radial artery catheterization can be difficult in patients with lower body weight and height due to smaller artery sizes. Ultrasound guidance may improve first-attempt success rates for radial artery catheterization.
Area of Science:
- Vascular Access Procedures
- Medical Ultrasound Applications
- Patient Safety in Interventions
Background:
- Radial artery catheterization for invasive blood pressure monitoring often relies on palpation.
- Ultrasound is typically a secondary tool for radial artery catheterization, used after failed palpation attempts.
- Primary ultrasound guidance may offer advantages over palpation for radial artery catheterization.
Purpose of the Study:
- To identify factors contributing to difficult radial artery catheterization.
- To evaluate patient characteristics associated with challenging radial artery cannulation.
- To determine predictors of prolonged radial artery catheterization time.
Main Methods:
- Radial artery ultrasound assessments were conducted pre-operatively in patients requiring invasive blood pressure monitoring.
- Radial artery catheterization was performed by operators blinded to ultrasound findings.
- Patients were categorized into uncomplicated (one attempt) and difficult (multiple attempts) catheterization groups.
Main Results:
- Patients with difficult radial artery catheterization had significantly lower body weight, height, and body surface area (BSA).
- Internal radial artery diameters were significantly smaller in the difficult catheterization group.
- Lower body weight, BMI, and BSA, along with reduced radial artery diameter, were associated with prolonged cannulation time.
Conclusions:
- Radial artery catheterization via palpation can be challenging in adult patients with lower body weight and height due to smaller arterial dimensions.
- Routine ultrasound use in patients with these characteristics may decrease first-attempt failures.
- Early ultrasound application can prevent procedural delays and reduce patient discomfort during radial artery catheterization.
Related Concept Videos
Cardiac Catheterization IV: Nursing Management
Pre-Procedural Guidelines for Assessing Blood Pressure
Cardiac Catheterization I: Pre-Procedure Overview
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Cardiac Catheterization II: Right Heart Catheterization
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation