Related Experiment Video
Updated: Aug 5, 2025

Pulse Wave Velocity Testing in the Baltimore Longitudinal Study of Aging
Published on: February 7, 2014
Wearable Continuous Blood Pressure Monitoring Devices Based on Pulse Wave Transit Time and Pulse Arrival Time: A
Zi-Bo Zhou1,2,3, Tian-Rui Cui1,2, Ding Li1,2
1School of Integrated Circuit, Tsinghua University, Beijing 100084, China.
Abstract:
Continuous blood pressure (BP) monitoring is of great significance for the real-time monitoring and early prevention of cardiovascular diseases. Recently, wearable BP monitoring devices have made great progress in the development of daily BP monitoring because they adapt to long-term and high-comfort wear requirements. However, the research and development of wearable continuous BP monitoring devices still face great challenges such as obvious motion noise and slow dynamic response speeds. The pulse wave transit time method which is combined with photoplethysmography (PPG) waves and electrocardiogram (ECG) waves for continuous BP monitoring has received wide attention due to its advantages in terms of excellent dynamic response characteristics and high accuracy. Here, we review the recent state-of-art wearable continuous BP monitoring devices and related technology based on the pulse wave transit time; their measuring principles, design methods, preparation processes, and properties are analyzed in detail. In addition, the potential development directions and challenges of wearable continuous BP monitoring devices based on the pulse wave transit time method are discussed.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Holter Monitor: 24-Hour Monitoring
Pulse Assessment Sites
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:

