Related Experiment Video
Updated: Aug 5, 2025

Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
Stabilization of Comminuted Fractures of the Proximal Humerus with Intramedullary Nails and Angularly Stable Locking
Karol Ratajczak1, Grzegorz Szczęsny1, Wiesław Tomaszewski2
1Department of Orthopedic Surgery and Traumatology, Medical University, 02-005 Warsaw, Poland.
Abstract:
Background and Objectives: Intramedullary nailing (IMN) and angularly stable plating (ASP) are the most popular techniques for the stabilization of comminuted fractures of the proximal humerus, without either one being obviously superior. The aim of the study was to validate the functional outcomes of both stabilization techniques in the COVID-19 pandemic by comparing them with data obtained just before the pandemic, because the limitations of the COVID-19 pandemic are affecting several aspects of social and medical life-being afraid of the transmission of the infection, patients reduce their exposure to healthcare to absolutely essential emergencies. Moreover, working conditions in the operating theater have also become more restrictive. Materials and Methods: Investigations were performed on 112 adult patients with Neer's three- and four-fragment fractures stabilized with IMN (64) and ASP (48). Treatment effects were validated six months after surgery based on radiographs for evidence of bone union, humeral neck-shaft angle (NSA) and implant placement. Limb function was assessed with the QuickDash and Constant-Murley scores. Data obtained from patients treated in the COVID-19 pandemic were compared with those obtained before the pandemic. Results: The healing of all fractures was satisfactory, but complications developed in six cases. Three patients required secondary interventions due to inadequate repositioning: one after IMN and two after ASP. Additionally, one ASP was complicated by the secondary destabilization of a primarily properly stabilized major tubercle, and in two cases by conflict of the protruding implant with the acromion. ASP was noted to provide better functional results during the COVID-19 pandemic according to the Constant-Murley score (p = 0.0048; Student's t-test). No significant differences were observed in the pre-COVID-19 pandemic. Conclusions: Our results suggest that ASP is more beneficial for the stabilization of comminuted fractures of the proximal humerus during the COVID-19 pandemic.
More Related Videos
07:41An Intramedullary Locking Nail for Standardized Fixation of Femur Osteotomies to Analyze Normal and Defective Bone Healing in Mice
Published on: November 13, 2016
15:11Surgical Fixation of Sternal Fractures: Preoperative Planning and a Safe Surgical Technique Using Locked Titanium Plates and Depth Limited Drilling
Published on: January 5, 2015