Related Experiment Video
Updated: Aug 5, 2025

A Package of Established Analytical Tools to Investigate the Solid-State Alteration of Lipid-Based Excipients
Published on: August 9, 2022
Identification of Sildenafil Compound in Selected Drugs Using X-ray Study and Thermal Analysis
Izabela Jendrzejewska1, Tomasz Goryczka2, Ewa Pietrasik1
1Institute of Chemistry, University of Silesia, Szkolna 9, 40007 Katowice, Poland.
Abstract:
Twelve drugs containing sildenafil compounds (sildenafil citrate and sildenafil base) were examined using X-ray studies and thermal analysis. According to the manufacturer's information, the presence of sildenafil was confirmed in all investigated drugs. The positions of diffraction lines (value of 2θ angle) agree with the patterns presented in the ICDD database, Release 2018 (ICDD-International Centre of Diffraction Data). The difference expresses the agreement in the position of the diffraction line between the tested substance and the standard. A good agreement is when this difference is less than 0.2°. The values of interplanar distances d are also compatible with the ICDD database. It indicated that the drug examined was genuine. Because all drugs are mixtures of different substances (API and excipients), the various diffraction line intensities were detected in all observed X-ray images for the tested drugs. The intensity of the diffraction line depends on many factors, like the amount of substance, coexisting phases, and mass absorption coefficient of the mixture. The thermal analysis confirmed the results obtained by the X-ray study. On DSC curves, the endothermic peaks for sildenafil compounds were observed. The determined melting points of sildenafil compounds corresponded to the values available in the literature. The results gathered by connecting two methods, X-ray study and thermal analysis, can help identify irregularities that may exist in pharmaceutical specimens, e.g., distinguishing genuine from counterfeit products, the presence of a correct polymorph, a lack of active substance, an inaccurate amount of the active substance, or excipients in the tested drug.
More Related Videos
09:24Application and Methodology of the Non-destructive 19F Time-domain NMR Technique to Measure the Content in Fluorine-containing Drug Products
Published on: August 22, 2017
07:05Correlative Optical Spectroscopy and Mass Spectrometry Imaging Methodology to Visualise Drug Distribution in a Soft Tissue Section
Published on: June 20, 2025
Related Concept Videos
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal...
Structure-Activity Relationships and Drug Design
SAR studies the intricate relationship between a drug's chemical structure and biological activity. It focuses on understanding how modifications to a drug's structure can influence...