Marianna Maspero1,2, Khaled Ali1, Beatrice Cazzaniga1
1Transplantation Center, Digestive Disease and Surgery Institute, Cleveland Clinic, Cleveland, Ohio.
Background And Aims:
Acute cellular rejection (ACR) is a frequent complication after liver transplantation. By reducing ischemia and graft damage, dynamic preservation techniques may diminish ACR. We performed a systematic review to assess the effect of currently tested organ perfusion (OP) approaches versus static cold storage (SCS) on post-transplant ACR-rates.
Approach And Results:
A systematic search of Medline, Embase, Cochrane Library, and Web of Science was conducted. Studies reporting ACR-rates between OP and SCS and comprising at least 10 liver transplants performed with either hypothermic oxygenated perfusion (HOPE), normothermic machine perfusion, or normothermic regional perfusion were included. Studies with mixed perfusion approaches were excluded. Eight studies were identified (226 patients in OP and 330 in SCS). Six studies were on HOPE, one on normothermic machine perfusion, and one on normothermic regional perfusion. At meta-analysis, OP was associated with a reduction in ACR compared with SCS [OR: 0.55 (95% CI, 0.33-0.91), p =0.02]. This effect remained significant when considering HOPE alone [OR: 0.54 (95% CI, 0.29-1), p =0.05], in a subgroup analysis of studies including only grafts from donation after cardiac death [OR: 0.43 (0.20-0.91) p =0.03], and in HOPE studies with only donation after cardiac death grafts [OR: 0.37 (0.14-1), p =0.05].
Conclusions:
Dynamic OP techniques are associated with a reduction in ACR after liver transplantation compared with SCS. PROSPERO registration: CRD42022348356.
More Related Videos
09:29Technique of Subnormothermic Ex Vivo Liver Perfusion for the Storage, Assessment, and Repair of Marginal Liver Grafts
Published on: August 13, 2014
11:26Heterotopic Auxiliary Whole Liver Rat Transplant Model Utilizing a Hepaticoureterostomy for Allograft Rejection Studies
Published on: March 8, 2024
Related Concept Videos
Kidney Transplant II: Surgical Procedure
Kidney Transplant I: Introduction