Correlating volumetric and linear measurements of brain metastases on MRI scans using intelligent automation
Burak B Ozkara1, Christian Federau2, Samir A Dagher1
1Department of Neuroradiology, MD Anderson Cancer Center, 1400 Pressler Street, Houston, TX, 77030, USA.
Purpose:
The Response Assessment in Neuro-Oncology Brain Metastases (RANO-BM) working group proposed a guide for treatment responses for BMs by utilizing the longest diameter; however, despite recognizing that many patients with BMs have sub-centimeter lesions, the group referred to these lesions as unmeasurable due to issues with repeatability and interpretation. In light of RANO-BM recommendations, we aimed to correlate linear and volumetric measurements in sub-centimeter BMs on contrast-enhanced MRI using intelligent automation software.
Methods:
In this retrospective study, patients with BMs scanned with MRI between January 1, 2018, and December 31, 2021, were screened. Inclusion criteria were: (1) at least one sub-centimeter BM with an integer millimeter-longest diameter was noted in the MRI report; (2) patients were a minimum of 18 years of age; (3) patients with available pre-treatment three-dimensional T1-weighted spoiled gradient-echo MRI scan. The screening was terminated when there were 20 lesions in each group. Lesion volumes were measured with the help of intelligent automation software Jazz (AI Medical, Zollikon, Switzerland) by two readers. The Kruskal-Wallis test was used to compare volumetric differences.
Results:
Our study included 180 patients. The agreement for volumetric measurements was excellent between the two readers. The volumes of the following groups were not significantly different: 1-2 mm, 1-3 mm, 1-4 mm, 2-3 mm, 2-4 mm, 3-4 mm, 3-5 mm, 4-5 mm, 5-6 mm, 5-7 mm, 6-7 mm, 6-8 mm, 6-9 mm, 7-8 mm, 7-9 mm, 8-9 mm.
Conclusion:
Our findings indicate that the largest diameter of a lesion may not accurately represent its volume. Additional research is required to determine which method is superior for measuring radiologic response to therapy and which parameter correlates best with clinical improvement or deterioration.