Ana Campos1, Pedro Cebola2, Sara Simões Dias3
1Otorhinolaryngology Clinical Academic Nucleus, Hospital CUF Tejo, Lisbon, Portugal.
Objective:
To evaluate the association between results from drug-induced sleep endoscopy (DISE) and computed tomography with lateral cephalometry (CTLC) of the pharynx in obstructive sleep apnea (OSA) patients, regarding the same anatomic level, in order to understand if CTLC could replace DISE in selected patients.
Study Design:
Cross-sectional.
Setting:
Tertiary hospital.
Methods:
A total of 71 patients who attended the Sleep Medicine Consultation in the Otorhinolaryngology Department of Hospital CUF Tejo between 1.6.2019 and 30.9.2021, performed a polysomnographic sleep study and were elected to undergo DISE and CTLC of the pharynx for diagnostic purposes were selected. Obstructions at the same anatomic levels - tongue base, epiglottis and velum - were compared in both exams.
Results:
Patients with reduction of epiglottis-pharynx space on CTLC had also a complete obstruction at epiglottis level on the VOTE classification of DISE (p = 0,027). Reduction of velum-pharynx space or tongue base-pharynx space were not related to complete obstruction of the velum (P = 0,623) or the tongue base (p = 0,594) found in DISE. Those with two or more space reductions had a tendency to multilevel obstruction observed in DISE (p = 0.089).
Conclusion:
When evaluating the obstruction level(s) of an OSA patient, efforts should be made to perform DISE, since CTLC measures, though regarding at the same structures, don´t correlate completely with obstructions observed in DISE.