Fiber Optic Temperature Sensor System Using Air-Filled Fabry-Pérot Cavity with Variable Pressure.
Hasanur R Chowdhury1, Ming Han1
1Electrical and Computer Engineering Department, Michigan State University, East Lansing, MI 48824, USA.
Sensors (Basel, Switzerland)
|March 30, 2023
Summary
This study presents a high-resolution fiber optic temperature sensor. Utilizing an air-filled Fabry-Pérot (FP) cavity, it achieves precise temperature measurements up to 800°C with excellent stability.
Area of Science:
- Optics and Photonics
- Sensor Technology
- Materials Science
Background:
- Fiber optic sensors offer advantages in harsh environments.
- Accurate temperature sensing is crucial in various industrial and scientific applications.
- Fabry-Pérot (FP) cavities are sensitive to environmental changes, including pressure and temperature.
Purpose of the Study:
- To develop and demonstrate a high-resolution fiber optic temperature sensor system.
- To investigate the use of an air-filled FP cavity for absolute temperature measurement.
- To analyze the impact of pressure variation and wavelength resolution on temperature sensing accuracy.
Main Methods:
- Fabrication of an air-filled FP cavity using fused-silica and single-mode/side-hole fibers.
- Utilizing spectral fringe shifts caused by controlled pressure variations within the cavity.
- Developing a computer-controlled pressure system and sensor interrogation system for precise measurements.
- Analyzing the relationship between wavelength resolution, pressure fluctuation, and temperature measurement resolution.
Main Results:
- Achieved high wavelength resolution (<0.2 pm) and minimal pressure fluctuation (~0.015 kPa).
- Demonstrated high-resolution temperature measurement with an accuracy of ±0.32 ℃.
- Validated sensor stability through thermal cycle testing up to 800 ℃.
Conclusions:
- The developed fiber optic FP sensor system enables high-resolution absolute temperature measurements.
- Precise control over cavity pressure and high spectral resolution are key to accurate sensing.
- The sensor exhibits excellent stability and potential for high-temperature applications.
Related Concept Videos
Measurement of Fluid Pressure
256
Fluid pressure is commonly measured using devices called manometers, which rely on liquid columns to indicate pressure differences. The height of a liquid column in a manometer reflects the pressure exerted by the fluid, providing a simple yet effective means of measurement. Different types of manometers serve specific purposes based on their configurations and the type of fluids involved.
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
256
Temperature Measurement Sites
1.9K
A thermometer measures body temperature. The common sites for measuring body temperature are the oral cavity, axillary region, temporal artery, and skin surface, such as the forehead, abdomen, and axilla. True core body temperature is assessed in the rectum, tympanic membrane, pulmonary artery, esophagus, and urinary bladder.
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
1.9K