Intrapartum cardiotocographic monitoring and its correlation with neonatal outcome
Suraj Kumar Singh1, Rakesh Kumar2, Anand Agarwal3
1Department of Neonatology, Himalayan Institute of Medical Sciences, Swami Rama Himalayan University, Dehradun, Uttarakhand, India.
Introduction:
Despite the advancements in perinatal care in past decades, perinatal asphyxia remains a serious problem leading to significant perinatal morbidity and mortality. Therefore, foetal monitoring during the intrapartum period is of paramount importance. Among various methods of fetal monitoring, cardiotocography is a form of electronic foetal monitoring in which there is simultaneous recording of foetal heart rate and uterine contractions.
Materials And Methods:
This cross-sectional observational study was done in the labour room and neonatal intensive care unit (NICU) of a teaching Municipal Hospital in North India including 500 pregnant women of age group 18-45 years with singeleton fetus of gestation ≥36 weeks without any known congenital anomaly. Intrapartum cardiotocography (CTG) for 20 minutes was done within 12 hours prior to delivery and babies born to them were observed for birth asphyxia as Apgar score <7 at 1 minute as per using APGAR score less than 7 at 1 minute as per south east asia regional neonatal perinatal database (SEAR-NPD), world health organization (WHO) working definition.
Results:
CTG tracing was normal/reassuring in 92% of pregnant women, nonreassuring in 7% and was abnormal in only 1%. In patients with abnormal and nonreassuring CTG, delivery by lower segment cesarian section (LSCS) was significantly high (P < .0001). APGAR scoring was done at 1 minute and 5 minutes of life, it was found that 4% babies were having score less than 7 at 1 minute with incidence of birth asphyxia 40 per 1,000 live births Neonatal seizure was significantly more in nonreassuring and abnormal CTG group (P value <.0001).
Conclusion:
Abnormal CTG tracings result in higher incidence of operative interventions for deliveries. Abnormal CTG pattern during intrapartum CTG has high specificity and negative predictive value but has low sensitivity and positive predictive value for detection of birth asphyxia and need for NICU admission.
Related Concept Videos
Fetal Circulation
Two umbilical arteries transport blood from the fetus to the placenta. At the placenta, the blood absorbs oxygen and nutrients while simultaneously eliminating waste products. This oxygen-enriched and nutrient-rich blood then returns to the fetus through one...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...