A High-throughput Method for Measurement of Glomerular Filtration Rate in Conscious Mice
Published on: May 10, 2013
Accuracy of GFR Estimating Equations in Patients with Discordances between Creatinine and Cystatin C-Based
Edouard L Fu1,2,3, Andrew S Levey4, Josef Coresh5
1Division of Pharmacoepidemiology and Pharmacoeconomics, Department of Medicine, Harvard Medical School, Brigham and Women's Hospital, Boston, Massachusetts.
Significance Statement:
Large discordances between eGFR on the basis of creatinine (eGFR cr ) or cystatin C (eGFR cys ) are common in clinical practice. However, which GFR estimating equation (eGFR cr , eGFR cys , or eGFR cr-cys ) is most accurate in these settings is not known. In this real-world study of 9404 concurrent measurements of creatinine, cystatin C, and iohexol clearance, all three equations performed similarly when eGFR cr and eGFR cys were similar (45% of cases). However, with large discordances (55% of cases), eGFR cr-cys was much more accurate than either alone. These findings were consistent among individuals with cardiovascular disease, heart failure, diabetes mellitus, liver disease, and cancer who have been underrepresented in research cohorts. Thus, when eGFR cr and eGFR cys are largely discordant in clinical practice, eGFR cr-cys is more accurate than eGFR cr or eGFR cys .
Background:
Cystatin C is recommended as a confirmatory test to eGFR when more precise estimates are needed for clinical decision making. Although eGFR on the basis of both creatinine and cystatin (eGFR cr-cys ) is the most accurate estimate in research studies, it is uncertain whether this is true in real-world settings, particularly when there are large discordances between eGFR based on creatinine (eGFR cr ) and that based on cystatin C (eGFR cys ).
Methods:
We included 6185 adults referred for measured GFR (mGFR) using plasma clearance of iohexol in Stockholm, Sweden, who had 9404 concurrent measurements of creatinine, cystatin C, and iohexol clearance. The performance of eGFR cr , eGFR cys , and eGFR cr-cys was assessed against mGFR with median bias, P30 , and correct classification of GFR categories. We stratified analyses within three categories: eGFR cys at least 20% lower than eGFR cr (eGFR cys
Results:
eGFR cr and eGFR cys were similar in 4226 (45%) samples, and among these samples all three estimating equations performed similarly. By contrast, eGFR cr-cys was much more accurate in cases of discordance. For example, when eGFR cys
Conclusions:
When eGFR cr and eGFR cys are highly discordant in clinical practice, eGFR cr-cys is more accurate than either eGFR cr or eGFR cys .
Related Concept Videos
Factors Affecting Renal Clearance: Renal Impairment
One condition associated with renal failure is uremia. Uremia is characterized by impaired glomerular filtration and fluid accumulation in the body. This condition hinders the renal clearance of drugs, resulting in drug accumulation and potential...
Renal Clearance
Renal clearance refers to the volume of plasma cleared of a specific substance, such as creatinine, per unit of time. To measure clearance, urine samples are collected over a 24-hour period during each bladder voiding, followed by a single blood sample at the...
Renal Failure: Dose Adjustments
Reduced renal clearance and elimination rate are common outcomes of renal impairment. These alterations lead to a prolonged elimination half-life and an altered apparent volume of distribution for drugs. As a result, dosage adjustments are typically necessary to maintain optimal drug levels in the body.
However, dosage adjustments...
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
Serum Studies: Renal Function Tests
Determination of Renal Drug Clearance: Graphical and Midpoint Methods
The graphical method involves plotting the rate of drug excretion in urine against the plasma drug concentration. By analyzing the graph, the clearance can be calculated and obtained. Drugs rapidly excreted by the kidneys exhibit a...