Differences in Electrical Delay Between the Mid-septum and Apex with the Right Ventricular Lead: Novel Implications
Fani Zagkli1, Katerina Trigka1, Rafail Koros1
1University Hospital of Patras, Department of Cardiology, Greece.
Abstract:
Ventricular sensing relies on the analysis of a local intracardiac electrogram in reference to the QRS on the surface electrocardiogram. If both signals do not coincide in time, there is a delay in sensing intrinsic ventricular activity. We evaluated possible differences in the electrical delay between the mid-septum and apex as determined by the right ventricular (RV) lead position using a pacing system analyzer (PSA) during conventional pacemaker implantation. Patients without significant heart disease and intrinsic atrioventricular conduction underwent their first Medtronic (Minneapolis, MN, USA) or Abbott (Chicago, IL, USA) dual-chamber pacemaker implantation with the RV lead first positioned at the apex and then subsequently at the mid-septum. Real-time ventricular sensing data were obtained through PSA to determine the electrical delay Q-VS value as the time difference between the QRS and the released RV-sensed event marker "VS." Among 212 patients, 139 had narrow QRS and 73 had complete right bundle branch block (RBBB). Overall, both narrow QRS and RBBB patients exhibited shorter Q-VS lengths at the mid-septum compared to the apex (50.4 ± 24.2 ms and 66.7 ± 32.3 ms vs. 63.9 ± 27.6 ms and 71.7 ± 32.2 ms; P < .0001 and P < .001, respectively). The Q-VS in patients with Abbott devices was significantly shorter compared to that in patients with Medtronic devices at both the mid-septum and the apex in both patient groups (P < .0001). In conclusion, RV lead positioning at the mid-septum is associated with a shorter electrical delay compared to positioning at the apex in both narrow QRS and RBBB patients.
More Related Videos
09:52Optocardiography and Electrophysiology Studies of Ex Vivo Langendorff-perfused Hearts
Published on: November 7, 2019
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
Related Concept Videos
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
Electrophysiology of Normal Cardiac Rhythm
Dysrhythmias IV: Characteristics of Bradyarrhythmias
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias