Related Experiment Video
Updated: Aug 4, 2025

A Novel Tenorrhaphy Suture Technique with Tissue Engineered Collagen Graft to Repair Large Tendon Defects
Published on: December 10, 2021
Artificial PGA/Collagen-based Bilayer Conduit in Short Gap Interposition Setting Provides Comparable Regenerative
Yu Li1,2, Keisuke Takanari1, Ryota Nakamura1
1Department of Plastic and Reconstructive Surgery, Aichi Cancer Center, Nagoya, Japan.
Abstract:
The aim of this study was to evaluate whether the Nerbridge, an artificial polyglycolic acid conduit with collagen matrix, is comparable to direct nerve suture in a rat sciatic nerve injury model in a short-gap interposition (SGI) setting.
Methods:
Sixty-six female Lewis rats were randomly divided into the sham group (n = 13); no reconstruction (no-recon) group (n = 13; rat model with 10 mm sciatic nerve defect); direct group (n = 20; rat sciatic nerve injury directly connected by 10-0 Nylon); and SGI group (n = 20; sciatic nerve injury repaired using 5-mm Nerbridge). Motor function and histological recovery were evaluated. The sciatic nerve and gastrocnemius muscle were harvested for quantification of the degree of nerve regeneration and muscle atrophy.
Results:
The SGI and direct groups achieved equal recovery in both functional and histological outcomes. At weeks 3 and 8 postsurgery, there was a significant improvement in the sciatic functional index of the SGI group when compared with that of the no-recon group (P < 0.05). Furthermore, the direct and SGI groups had less muscle atrophy at 4 and 8 weeks postsurgery compared with the no-recon group (P < 0.05). The axon density and diameter at the distal site in the SGI group were significantly higher than that in the no-recon group and comparable to that in the direct and sham groups.
Conclusion:
An artificial nerve conduit has equal potential as direct suture in motor nerve reconstruction when used in the SGI setting.