Single-heartbeat cardiac cine imaging via jointly regularized nonrigid motion-corrected reconstruction
Gastao Cruz1, Kerstin Hammernik2,3, Thomas Kuestner1,4
1School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.
None:
The aim of the current study was to develop a novel approach for 2D breath-hold cardiac cine imaging from a single heartbeat, by combining cardiac motion-corrected reconstructions and nonrigidly aligned patch-based regularization. Conventional cardiac cine imaging is obtained via motion-resolved reconstructions of data acquired over multiple heartbeats. Here, we achieve single-heartbeat cine imaging by incorporating nonrigid cardiac motion correction into the reconstruction of each cardiac phase, in conjunction with a motion-aligned patch-based regularization. The proposed Motion-Corrected CINE (MC-CINE) incorporates all acquired data into the reconstruction of each (motion-corrected) cardiac phase, resulting in a better posed problem than motion-resolved approaches. MC-CINE was compared with iterative sensitivity encoding (itSENSE) and Extra-Dimensional Golden Angle Radial Sparse Parallel (XD-GRASP) in 14 healthy subjects in terms of image sharpness, reader scoring (range: 1-5) and reader ranking (range: 1-9) of image quality, and single-slice left ventricular assessment. MC-CINE was significantly superior to both itSENSE and XD-GRASP using 20 heartbeats, two heartbeats, and one heartbeat. Iterative SENSE, XD-GRASP, and MC-CINE achieved a sharpness of 74%, 74%, and 82% using 20 heartbeats, and 53%, 66%, and 82% with one heartbeat, respectively. The corresponding results for reader scoring were 4.0, 4.7, and 4.9 with 20 heartbeats, and 1.1, 3.0, and 3.9 with one heartbeat. The corresponding results for reader ranking were 5.3, 7.3, and 8.6 with 20 heartbeats, and 1.0, 3.2, and 5.4 with one heartbeat. MC-CINE using a single heartbeat presented nonsignificant differences in image quality to itSENSE with 20 heartbeats. MC-CINE and XD-GRASP at one heartbeat both presented a nonsignificant negative bias of less than 2% in ejection fraction relative to the reference itSENSE. It was concluded that the proposed MC-CINE significantly improves image quality relative to itSENSE and XD-GRASP, enabling 2D cine from a single heartbeat.
Related Concept Videos
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...