Related Experiment Video
Updated: Aug 4, 2025

A Detailed Protocol for Physiological Parameters Acquisition and Analysis in Neurosurgical Critical Patients
Published on: October 17, 2017
Correlation between retinal vein pulse amplitude, estimated intracranial pressure, and postural change
W H Morgan1,2, J Khoo3, A Vukmirovic3,4
1Lions Eye Institute, Centre for Ophthalmology and Visual Science, University of Western Australia, Perth, WA, Australia. bill.morgan@uwa.edu.au.
Abstract:
Spaceflight associated neuro-ocular syndrome (SANS) is common amongst astronauts on long duration space missions and is associated with signs consistent with elevated cerebrospinal fluid (CSF) pressure. Additionally, CSF pressure has been found to be elevated in a significant proportion of astronauts in whom lumbar puncture was performed after successful mission completion. We have developed a retinal photoplethysmographic technique to measure retinal vein pulsation amplitudes. This technique has enabled the development of a non-invasive CSF pressure measurement apparatus. We tested the system on healthy volunteers in the sitting and supine posture to mimic the range of tilt table extremes and estimated the induced CSF pressure change using measurements from the CSF hydrostatic indifferent point. We found a significant relationship between pulsation amplitude change and estimated CSF pressure change (p < 0.0001) across a range from 2.7 to 7.1 mmHg. The increase in pulse amplitude was highest in the sitting posture with greater estimated CSF pressure increase (p < 0.0001), in keeping with physiologically predicted CSF pressure response. This technique may be useful for non-invasive measurement of CSF pressure fluctuations during long-term space voyages.
More Related Videos
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Measurement of Blood Pressure
Blood Pressure
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Pre-Procedural Guidelines for Assessing Blood Pressure

