Using a contralateral shoe lift to reduce gait deterioration during an offloading fast-walk setting in diabetic
Nikolas Beauchesne1, Alice Wagenaar-Tison2, Magali Brousseau-Foley3
1Department of Human Kinetics and Podiatric Medicine, Université du Québec à Trois-Rivières, 3351, boul. des Forges, C.P. 500, Trois-Rivières G9A 5H7, Canada.
Aims:
Diabetic peripheral neuropathy (DPN) is a predictor of foot ulcers and leads to sedentary behaviour. This comparative study evaluated gait and feasibility of a 20-minute fast walk, at 40-60% of cardiopulmonary capacity, in individuals with DPN wearing an offloading boot and a contralateral shoe balancer.
Methods:
Gait parameters were measured with inertial sensors on 32 individuals (group with DPN [n = 16], group with diabetes but without DPN [n = 9], and a group without diabetes/DPN [n = 7]). Feasibility was assessed by feedback on perceived effort and adverse events. Gait outcomes were compared between groups with or without a shoe balancer using one-way ANOVAs.
Results:
The three groups were equivalent in terms of activity level and age and gender except for the body mass index. Both groups with diabetes exhibited minimal decreased gait speed (p > 0.005) and the DPN group exhibited increased double-support percentage (+4.6%, p = 0.01) while walking with an offloading boot and contralateral shoe balancer. The use of a contralateral shoe balancer reduced gait asymmetry. Lower physical activity level was associated with further gait deterioration in all groups. Few adverse events were reported, and 91% of participants reported that the proposed activity would be feasible daily.
Conclusions:
The offloading boot deteriorated gait function, but a contralateral shoe balancer minimized its impact, especially in the context of physical activity in people with diabetes and DPN.
Related Concept Videos
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Peripheral Artery Disease IV: Nursing Management