Related Experiment Video
Updated: Aug 4, 2025

Emergency Undocking in Robotic Surgery: A Simulation Curriculum
Published on: May 20, 2018
In Situ Simulation as a Quality Improvement Tool to Identify and Mitigate Latent Safety Threats for Emergency
Background:
In situ simulation has emerged as a powerful quality improvement (QI) tool in the identification of latent safety threats (LSTs). Following the first wave of SARS-CoV-2 at an urban epicenter of the disease, a multi-institutional collaborative was formed to integrate an in situ simulation protocol across five emergency departments (EDs) for systems improvement of acute airway management.
Methods:
A prospective, multi-institutional QI initiative using two Plan-Do-Study-Act (PDSA) cycles was implemented across five EDs. Each institution conducted simulations involving mannequins in acute respiratory failure requiring definitive airways. Simulations and systems-based debriefs were standardized. LSTs were collected in an online database, focused on (1) equipment availability, (2) infection control, and (3) communication.
Results:
From June 2020 through May 2021, 58 of 70 (82.9%) planned simulations were completed across five sites with 328 unique individual participants. Overall LSTs per simulation (7.00-4.69, p < 0.001) and equipment LSTs (3.00-1.46, p < 0.001) decreased from cycle 1 to cycle 2. Changes in mean LSTs for infection control and communication categories varied among sites. There was no correlation between total LSTs or any of the categories and team size. Number of beds occupied was significantly negatively correlated with total and infection control LSTs.
Conclusion:
This study was unique in simultaneously running a structured in situ protocol across numerous diverse institutions during a global pandemic. This initiative found similar categories of threats across sites, and the protocol developed empowered participants to implement changes to mitigate identified threats.
More Related Videos
Related Concept Videos
Cardiopulmonary Resuscitation II: ACLS Airway Management
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Tracheostomy Suctioning I: Pre-Procedural Steps
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...