Related Experiment Video
Updated: Aug 4, 2025

Direct Pressure Monitoring Accurately Predicts Pulmonary Vein Occlusion During Cryoballoon Ablation
Published on: February 26, 2013
Pulmonary vein isolation for atrial fibrillation using true high-power short-duration vs. cryoballoon ablation
Jonas Wörmann1, Jakob Lüker2, Jan-Hendrik van den Bruck2
1Department of Electrophysiology, Heart Center, University of Cologne, Kerpener Str. 62, 50937, Cologne, Germany. jonas.woermann@uk-koeln.de.
Aims:
Pulmonary vein isolation (PVI) is achievable and effective using radiofrequency (RF) catheter (CA) or cryoballoon (CB) ablation. The newly introduced high RF-power short-duration ablation (HPSD) technique has shown promising results. Data comparing HPSD- to CB-PVI is sparse. We sought to investigate success rates and procedural differences of HPSD-PVI vs. CB-PVI in patients undergoing ablation for PAF and persAF.
Methods:
Consecutive patients undergoing de novo PVI (HPSD or CB) were included. A power setting of 70W/7 s (70W/5 s at posterior wall) using a flexible tip catheter with enhanced irrigation was considered as true HPSD. Follow-up consisted of out-clinic pts visits, tele-consultation, 48-h Holter ECG, app-based telemonitoring and cardiac implanted electronic devices (CIED) interrogation.
Results:
721 patients (46 HPSD, 675 CB) were analyzed. In all HPSD (27 persAF [59%]) and CB patients (423 persAF [63%]), PVI was successfully achieved. Procedure duration was significantly longer for HPSD (91 ± 19 min vs. 72 ± 18 min, p < 0.01). Ablation time was similar in both groups (HPSD: 44 ± 19 min vs. CB: 40 ± 17 min; p = 0.347). No major complications occurred in HPSD. For CB-PVI, in 25 (3.7%; p = 0.296) patients, complications occurred. At a follow-up of 290 ± 135 days, arrhythmia-free survival using HPSD was non-inferior to CB-PVI in the Kaplan-Meier survival analysis (p = 0.096).
Conclusion:
PVI using HPSD is equally effective and safe to CB-PVI. This analysis revealed a similar arrhythmia-free survival after HPSD and CB with low complication rates. Procedure duration for CB was significantly shorter while LA dwell time excluding mapping was equal. Currently, a prospective trial is conducted to corroborate these findings.