Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Double Resonance Techniques: Overview01:12

Double Resonance Techniques: Overview

253
Double resonance techniques in Nuclear Magnetic Resonance (NMR) spectroscopy involve the simultaneous application of two different frequencies or radiofrequency pulses to manipulate and observe two distinct nuclear spins. One important application of double resonance is spin decoupling, which selectively suppresses coupling with one type of nucleus while observing the NMR signal from another nucleus, simplifying the spectrum and enhancing resolution.
Spin decoupling is usually achieved by...
253
Characteristics of Series Resonant Circuit01:24

Characteristics of Series Resonant Circuit

290
Series resonance occurs in a circuit containing inductive (L), capacitive (C), and resistive (R) elements connected sequentially. At the resonance frequency, the inductive and capacitive reactances are equal in magnitude but opposite in sign, effectively canceling each other. This causes the circuit's impedance is minimal, primarily determined by the resistance R. The resonant frequency of an RLC circuit is defined as:
290
Parallel Resonance01:23

Parallel Resonance

242
The parallel RLC circuit is an arrangement where the resistor (R), inductor (L), and capacitor (C) are all connected to the same nodes and, as a result, share the same voltage across them. The parallel RLC circuit is analyzed in terms of admittance (Y), which reflects the ease with which current can flow. The admittance is given by:
242
Design Example01:23

Design Example

350
The innovation of touch-tone telephony revolutionized the telecommunications industry by replacing the traditional rotary dial with a dual-tone multi-frequency (DTMF) signaling system. This system uses a matrix-style keypad with buttons arranged in four rows and three columns, creating 12 distinct signals each assigned to a pair of frequencies. Each button press results in a simultaneous generation of two sinusoidal tones – one from a low-frequency group (697 to 941 Hz) and one from a...
350

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Global Linearized Sparse Prediction and Adaptive Dead Zone Compensation for a Piezoelectric Actuator.

Micromachines·2026
Same author

Full-Space Three-Dimensional Holograms Enabled by a Reflection-Transmission Integrated Reconfigurable Metasurface.

Nanomaterials (Basel, Switzerland)·2025
Same author

Hierarchical Crack Engineering-Enabled High-Linearity and Ultrasensitive Strain Sensors.

ACS sensors·2025
Same author

A temperature-compensated CO2 detection system based on non-dispersive infrared spectral technology.

The Review of scientific instruments·2024
Same author

Additively-Manufactured Broadband Metamaterial-Based Luneburg Lens for Flexible Beam Scanning.

Materials (Basel, Switzerland)·2024
Same author

Novel Surface Acoustic Wave Temperature-Strain Sensor Based on LiNbO<sub>3</sub> for Structural Health Monitoring.

Micromachines·2022
Same journal

Cluster assisted soft-landing hub (CLASH): An instrument for surface desorption and deposition using a pulsed cluster ion source.

The Review of scientific instruments·2026
Same journal

Influence of pre-ionization parameters on multi-channel discharge characteristics of field-distortion switch gaps.

The Review of scientific instruments·2026
Same journal

A Joule-Thomson low-temperature scanning tunneling microscope with vector magnet and rotatable scanning head.

The Review of scientific instruments·2026
Same journal

Fiber-optic triggering of a two-stage high-current linear transformer driver with laser energy below 100 μJ.

The Review of scientific instruments·2026
Same journal

Optimization of laboratory-scale x-ray absorption spectroscopy (XAS) apparatus for nuclear fuel research.

The Review of scientific instruments·2026
Same journal

Compressed multi-scale entropy and its application in mechanical fault diagnosis.

The Review of scientific instruments·2026
See all related articles

Related Experiment Video

Updated: Aug 4, 2025

Design and Characterization Methodology for Efficient Wide Range Tunable MEMS Filters
15:25

Design and Characterization Methodology for Efficient Wide Range Tunable MEMS Filters

Published on: February 4, 2018

6.2K

A wireless demodulation system based on a multi-parameter resonant sensor.

Hao Wang1, Xiaorui Liang1, Juan Zhang1

  • 1Science and Technology on Electronic Test and Measurement Laboratory, North University of China, Taiyuan 030051, China.

The Review of Scientific Instruments
|April 4, 2023
PubMed
Summary
This summary is machine-generated.

This study introduces a wireless passive measurement system for real-time multi-parameter detection. The system accurately demodulates signals from integrated sensors, demonstrating high precision in temperature and pressure measurements.

More Related Videos

Construction of a Wireless-Enabled Endoscopically Implantable Sensor for pH Monitoring with Zero-Bias Schottky Diode-based Receiver
08:25

Construction of a Wireless-Enabled Endoscopically Implantable Sensor for pH Monitoring with Zero-Bias Schottky Diode-based Receiver

Published on: August 27, 2021

2.6K
Microfluidic Platform with Multiplexed Electronic Detection for Spatial Tracking of Particles
11:54

Microfluidic Platform with Multiplexed Electronic Detection for Spatial Tracking of Particles

Published on: March 13, 2017

9.4K

Related Experiment Videos

Last Updated: Aug 4, 2025

Design and Characterization Methodology for Efficient Wide Range Tunable MEMS Filters
15:25

Design and Characterization Methodology for Efficient Wide Range Tunable MEMS Filters

Published on: February 4, 2018

6.2K
Construction of a Wireless-Enabled Endoscopically Implantable Sensor for pH Monitoring with Zero-Bias Schottky Diode-based Receiver
08:25

Construction of a Wireless-Enabled Endoscopically Implantable Sensor for pH Monitoring with Zero-Bias Schottky Diode-based Receiver

Published on: August 27, 2021

2.6K
Microfluidic Platform with Multiplexed Electronic Detection for Spatial Tracking of Particles
11:54

Microfluidic Platform with Multiplexed Electronic Detection for Spatial Tracking of Particles

Published on: March 13, 2017

9.4K

Area of Science:

  • Sensor Technology
  • Wireless Measurement Systems
  • Signal Processing

Background:

  • Integrated sensors are susceptible to interference from multiple environmental factors like temperature and pressure.
  • Accurate real-time acquisition and demodulation of multi-parameter sensor data are challenging due to crosstalk.
  • Existing systems may lack the flexibility and accuracy required for diverse industrial applications.

Purpose of the Study:

  • To propose and validate a novel wireless passive measurement system for real-time multi-parameter detection.
  • To develop and implement an algorithm for multi-parameter decoupling to mitigate crosstalk.
  • To create user-friendly software for sensor calibration and real-time demodulation, enhancing system usability.

Main Methods:

  • Development of a multi-parameter integrated sensor with a wide frequency detection range (25 MHz-2.7 GHz).
  • Design of an RF signal acquisition and demodulation circuit.
  • Implementation of a multi-functional host computer software featuring multi-parameter decoupling algorithms and sensor calibration.
  • Experimental verification using dual-reference integrated surface acoustic wave sensors for temperature and pressure measurements.

Main Results:

  • The signal acquisition circuit demonstrated high accuracy across a wide frequency range.
  • Sensor dynamic response detection results closely matched network analyzer data, with a maximum error of 0.96%.
  • The system achieved a maximum temperature measurement error of 1.51% and a maximum pressure measurement error of 5.136%.

Conclusions:

  • The proposed wireless passive measurement system exhibits excellent detection accuracy and demodulation performance.
  • The developed multi-parameter decoupling algorithm effectively addresses crosstalk issues in integrated sensors.
  • The system is suitable for real-time wireless detection and demodulation of multiple parameters, offering enhanced usability and flexibility.