Background:
Although the skin prick test (SPT) is a reliable procedure to confirm IgE-dependent allergic sensitization in patients, the interpretation of the test is still performed manually, resulting in an error-prone procedure for the diagnosis of allergic diseases.
Objective:
To design and implement an innovative SPT evaluation framework using a low-cost, portable smartphone thermography, named Thermo-SPT, to significantly improve the accuracy and reliability of SPT outcomes.
Methods:
Thermographical images were captured every 60 s for a duration of 0 to 15 min using the FLIR One app, and then analysed with the FLIR Tool® . The definition of 'Skin Sensitization Region' area was introduced to analyse the time-lapse thermal changes in skin reactions over several time periods during the SPT. The Allergic Sensitization Index (ASI) and Min-Max Scaler Index (MMS) formulae were also developed to optimize the identification of the peak allergic response time point through the thermal assessment (TA) of allergic rhinitis patients.
Results:
In these experimental trials, a statistically significant increase in temperature was detected from the fifth minute of TA for all tested aeroallergens (all values ). An increase was observed in the number of false-positive cases, where patients with clinical symptoms not consistent with SPT were evaluated as positive on TA assessment, specifically for patients diagnosed with Phleum pratense and Dermatophagoides pteronyssinus. Our proposed technique, the MMS, has demonstrated improved accuracy in identifying P. pratense and D. pteronyssinus compared with other SPT evaluation metrics, specifically starting from the fifth minute. For patients diagnosed with Cat epithelium, although not statistically significant initially, an increasing trend was determined in the results at the 15 min (ΔT (T15 - T0 ), ; ASIT15 , ).
Conclusions:
This proposed SPT evaluation framework utilizing a low-cost, smartphone-based thermographical imaging technique can enhance the interpretability of allergic responses during the SPT, potentially reducing the need for extensive manual interpretation experience as standard SPTs.
Related Concept Videos
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Thermosensation
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...