A simple retarding-potential time-of-flight mass spectrometer for electrospray propulsion diagnostics
Christopher T Lyne1, Miron F Liu1, Joshua L Rovey1
1Department of Aerospace Engineering, University of Illinois Urbana-Champaign, Urbana, IL 61801 USA.
Abstract:
The time-of-flight mass spectrometer (ToF-MS) is a useful tool for quantifying the performance of electrospray thrusters and characterizing their plumes. ToF-MS data can be used to calculate the mass-to-charge distribution in the plume, but the kinetic-energy-to-charge (i.e., the potential) distribution must be known first. Here we use a ToF-MS in tandem with a retarding potential (RP) analyzer. By sweeping the retarding potential through the range of potentials present in the plume, both the mass-to-charge distribution and the potential distribution can be measured independently. We demonstrate this technique in a case study using a capillary electrospray emitter and the ionic liquid propellant 1-Ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide, abbreviated EMI-Im. We report a linear correlation between retarding potential and mass-to-charge ratio that agrees with published data from more complex orthogonal RP/ToF-MS instruments. Calculated values for the jet velocity and jet breakup potential match within 2% and 12%, respectively. Using conventional ToF-MS, we estimated the propellant flow rate and compared those estimates to direct flow rate measurements. For flow rates between 233 pL/s and 565 pL/s, the error in ToF-based flow rate estimates ranged from -16% to -13% when the plume potential was assumed to be a function of mass-to-charge. Assuming a constant plume potential yielded mixed results. However, using the average stopping potential measured by a retarding potential analyzer resulted in higher errors, ranging from -26% to -30%. Data and MATLAB code are included as supplemental materials so that readers can easily apply the techniques described here.
Supplementary Information:
The online version contains supplementary material available at 10.1007/s44205-023-00045-y.
More Related Videos
08:43PTR-ToF-MS Coupled with an Automated Sampling System and Tailored Data Analysis for Food Studies: Bioprocess Monitoring, Screening and Nose-space Analysis
Published on: May 11, 2017
09:18Time-resolved ElectroSpray Ionization Hydrogen-deuterium Exchange Mass Spectrometry for Studying Protein Structure and Dynamics
Published on: April 17, 2017
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Tandem Mass Spectrometry
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
Mass Analyzers: Common Types
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Mass Spectrometers
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview