Related Experiment Video
Updated: Aug 4, 2025

In Vitro Application of a Wireless Sensor in Flexion-Extension Gap Balance of Unicompartmental Knee Arthroplasty
Published on: May 5, 2023
No difference in mobile and fixed bearing partial knee arthroplasty in octogenarians: a clinical trial
Riccardo D'Ambrosi1,2, Federico Valli3, Alessandro Nuara3
1IRCCS Istituto Ortopedico Galeazzi, Milan, Italy. riccardo.dambrosi@hotmail.it.
Background:
A clinical trial comparing MB (mobile-bearing) versus FB (fixed-bearing) in medial partial knee arthroplasty (PKA) in octagenarians has been conducted. The focus of the present study was on PROMs, range of motion (ROM), implant positioning and implants survivorship. The hypothesis of the present study was that MB implants performed better than FB in PKA in octogenarians.
Methods:
The first group received FB PKA-PPK®; the second received MB PKA-Oxford. Patients were not randomly allocated. The following PROMs were administered at T0 (pre-operatively), T1 (1 year after surgery), and T2 (3 years after surgery): visual analogue scale (VAS), Knee Society Score (KSS) and Oxford Knee Score (OKS). Data regarding the implant survivorship and ROM were also collected. Furthermore, the following radiographic parameters were measured: Femoral component varus/valgus; Tibial component varus/valgus; Anteroposterior slope.
Results:
At T0, 28 patients were included in the FB and 33 in the MB group. The surgical time was shorter in the FB group (p < 0.001). No difference between FB and MB in ROM, VAS, KSS, and OKS at each follow-up (p > 0.05). No difference was found in implant positioning (p > 0.05). At last follow-up, FB group reported three failures caused by aseptic loosening. Four failures were observed in the MB cohort: two for bearing dislocation and two for aseptic loosening. The Kaplan-Meier Curve found no differences in implant survivorship.
Conclusions:
According to the main findings of the present clinical trial, MB implants performed similar to FB in PKA in octogenarians. The FB group demonstrated shorted surgical time. No difference was found in patient reported outcome measures, ROM, implant positioning, and survivorship.
Level Of Evidence:
Level II, prospective study.
More Related Videos
07:22Glycemic Impact on Knee Osteoarthritis Symptoms on Physical, Radiographic, and Inflammatory Markers among Individuals Aged 50 and Over with Diabetes
Published on: March 7, 2025
09:08Biotribological Testing and Analysis of Articular Cartilage Sliding against Metal for Implants
Published on: May 14, 2020