Sofia Peacock1,2, Isolda Frizelle2, Sufyan Hussain3,4,5
1Department of Diabetes, School of Cardiovascular, Metabolic Medicine and Sciences, King's College London, London, UK.
Introduction:
Several different forms of automated insulin delivery systems (AID systems) have recently been developed and are now licensed for type 1 diabetes (T1D). We undertook a systematic review of reported trials and real-world studies for commercial hybrid closed-loop (HCL) systems.
Methods:
Pivotal, phase III and real-world studies using commercial HCL systems that are currently approved for use in type 1 diabetes were reviewed with a devised protocol using the Medline database.
Results:
Fifty-nine studies were included in the systematic review (19 for 670G; 8 for 780G; 11 for Control-IQ; 14 for CamAPS FX; 4 for Diabeloop; and 3 for Omnipod 5). Twenty were real-world studies, and 39 were trials or sub-analyses. Twenty-three studies, including 17 additional studies, related to psychosocial outcomes and were analysed separately.
Conclusions:
These studies highlighted that HCL systems improve time In range (TIR) and arouse minimal concerns around severe hypoglycaemia. HCL systems are an effective and safe option for improving diabetes care. Real-world comparisons between systems and their effects on psychological outcomes require further study.
Related Concept Videos
Insulin Formulations: Types and Delivery
Short-acting insulins are divided into...
Insulin: Biosynthesis, Chemistry, and Preparation
Damage or functional impairment of β-cells inhibits insulin production, leading to diabetes. Diabetes treatment...
Insulin: Dosing Regimen and Adverse Effects
The basal dose constitutes about 40%-50% of the total daily dose, with the rest as premeal insulin. The mealtime insulin dose should mirror...
Open and closed-loop control systems
An open-loop control system operates without feedback from the output. It consists of two primary elements: the controller and the controlled process. The controller receives an input signal...
Hypoglycemia and Glucagon
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...