Comparison between Conventional Breath-hold and Respiratory-triggered Magnetic Resonance Cholangiopancreatography
Younguk Kim1, Eun Sun Lee1, Hyun Jeong Park1
1Department of Radiology, Chung-Ang University Hospital 102, Heukseok-ro, Dongjak-gu, Seoul 06973, Republic of Korea.
Introduction:
The application of compressed sensing (CS) has enabled breath-hold 3D-MRCP with a shorter acquisition time in clinical practice.
Aim:
To compare the image quality of breath-hold (BH) and respiratory-triggered (RT) 3D-MRCP with or without CS application in the same study population.
Methods:
In this retrospective study, from February to July 2020, a total of 98 consecutive patients underwent four different acquisition types of 3D-MRCP.; 1) BH MRCP with the generalized autocalibrating partially parallel acquisition (GRAPPA) (BH-GRAPPA), 2) RT-GRAPPA-MRCP, 3) RT-CSMRCP and 4) BH-CS-MRCP. Relative contrast of common bile duct, 5-scale visibility score of biliary pancreatic ducts, 3-scale artifact score and 5-scale overall image quality score were evaluated by two abdominal radiologists.
Results:
Relative contrast value was significantly higher in BH-CS or RT-CS than in RT-GRAPPA (0.90 ± 0.057 and 0.89 ± 0.079, respectively, vs. 0.82 ± 0.071, p < 0.01) or BH-GRAPPA (vs. 0.77 ± 0.080, p < 0.01). The area affected by artifact was significantly lower in BH-CS among 4 MRCPs (p < 0.01). Overall image quality score in BH-CS was significantly higher than BH-GRAPPA (3.40 vs. 2.71, p < 0.01). There were no significant differences between RT-GRAPPA and BH-CS (vs. 3.13, p = 0.67) in overall image quality.
Conclusion:
In this study, our results revealed BH-CS had higher relative contrast and comparable or superior image quality among four MRCP sequences.
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...