Related Experiment Video
Updated: Aug 4, 2025

Tilt Testing with Combined Lower Body Negative Pressure: a "Gold Standard" for Measuring Orthostatic Tolerance
Published on: March 21, 2013
Evaluation of pre-induction dynamic arterial elastance as an adjustable predictor of post-induction hypotension: A
Eun Jung Oh1, Jeong Jin Min2, Eunjin Kwon2
1Department of Anesthesiology and Pain Medicine, Gwangmyeong Hospital, Chung-Ang University School of Medicine, Gwangmyeong, Republic of Korea.
Study Objective:
Dynamic arterial elastance (Eadyn) has been suggested as a functional measure of arterial load. We aimed to evaluate whether pre-induction Eadyn can predict post-induction hypotension.
Design:
Prospective observational study.
Patients:
Adult patients undergoing general anesthesia with invasive and non-invasive arterial pressure monitoring systems.
Measurements:
We collected invasive and non-invasive Eadyns (n = 38 in each), respectively. In both invasive and non-invasive Eadyns, pre-induction Eadyns were obtained during one-minute tidal and deep breathing in each patient before anesthetic induction. Post-induction hypotension was defined as a decrease of >30% in mean blood pressure from the baseline value or any absolute mean blood pressure value of <65 mmHg for 10 min after anesthetic induction. The predictabilities of Eadyns for the development of post-induction hypotension were tested using receiver-operating characteristic curve analysis.
Main Results:
Invasive Eadyn during deep breathing showed significant predictability with an area under the curve (AUC) of 0.78 (95% Confidence interval [CI], 0.61-0.90, P = 0.001). But non-invasive Eadyn during tidal breathing (AUC = 0.66, 95% CI, 0.49-0.81, P = 0.096) and deep breathing (AUC = 0.53, 95% CI, 0.36-0.70, P = 0.75), and invasive Eadyn during tidal breathing (AUC = 0.66, 95% CI, 0.41-0.74, P = 0.095) failed to predict post-induction hypotension.
Conclusion:
In our study, invasive pre-induction Eadyn during deep breathing -could predict post-induction hypotension. Despite its invasiveness, future studies will be needed to evaluate the usefulness of Eadyn as a predictor of post-induction hypotension because it is an adjustable parameter.
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)
Measurement of Blood Pressure
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: