A Basic Positron Emission Tomography System Constructed to Locate a Radioactive Source in a Bi-dimensional Space
Published on: February 1, 2016
Experimental evaluation of convolutional neural network-based inter-crystal scattering recovery for high-resolution
Seungeun Lee1,2, Jae Sung Lee1,3
1Department of Nuclear Medicine, Seoul National University, Seoul, 03080, Republic of Korea.
Abstract:
Objective. One major limiting factor for achieving high resolution of positron emission tomography (PET) is a Compton scattering of the photon within the crystal, also known as inter-crystal scattering (ICS). We proposed and evaluated a convolutional neural network (CNN) named ICS-Net to recover ICS in light-sharing detectors for real implementations preceded by simulations. ICS-Net was designed to estimate the first-interacted row or column individually from the 8 × 8 photosensor amplitudes.Approach. We tested 8 × 8, 12 × 12, and 21 × 21 Lu2SiO5arrays with pitches of 3.2, 2.1, and 1.2 mm, respectively. We first performed simulations to measure the accuracies and error distances, comparing the results to previously studied pencil-beam-based CNN to investigate the rationality of implementing fan-beam-based ICS-Net. For experimental implementation, the training dataset was prepared by obtaining coincidences between the targeted row or column of the detector and a slab crystal on a reference detector. ICS-Net was applied to the detector pair measurements with moving a point source from the edge to center using automated stage to evaluate their intrinsic resolutions. We finally assessed the spatial resolution of the PET ring.Main results. The simulation results showed that ICS-Net improved the accuracy compared with the case without recovery, reducing the error distance. ICS-Net outperformed a pencil-beam CNN, which provided a rationale to implement a simplified fan-beam irradiation. With the experimentally trained ICS-Net, the degree of improvements in intrinsic resolutions were 20%, 31%, and 62% for the 8 × 8, 12 × 12, and 21 × 21 arrays, respectively. The impact was also shown in the ring acquisitions, achieving improvements of 11%-46%, 33%-50%, and 47%-64% (values differed from the radial offset) in volume resolutions of 8 × 8, 12 × 12, and 21 × 21 arrays, respectively.Significance. The experimental results demonstrate that ICS-Net can effectively improve the image quality of high-resolution PET using a small crystal pitch, requiring a simplified setup for training dataset acquisition.
More Related Videos
10:24Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor
Published on: May 7, 2021
09:55Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
Published on: October 4, 2024
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET