Related Experiment Video
Updated: Aug 4, 2025

Ultrasonic Assessment of Myocardial Microstructure
Published on: January 14, 2014
Blinded, randomized trial of sonographer versus AI cardiac function assessment
Bryan He1, Alan C Kwan2, Jae Hyung Cho2
1Department of Computer Science, Stanford University, Palo Alto, CA, USA.
Abstract:
Artificial intelligence (AI) has been developed for echocardiography1-3, although it has not yet been tested with blinding and randomization. Here we designed a blinded, randomized non-inferiority clinical trial (ClinicalTrials.gov ID: NCT05140642; no outside funding) of AI versus sonographer initial assessment of left ventricular ejection fraction (LVEF) to evaluate the impact of AI in the interpretation workflow. The primary end point was the change in the LVEF between initial AI or sonographer assessment and final cardiologist assessment, evaluated by the proportion of studies with substantial change (more than 5% change). From 3,769 echocardiographic studies screened, 274 studies were excluded owing to poor image quality. The proportion of studies substantially changed was 16.8% in the AI group and 27.2% in the sonographer group (difference of -10.4%, 95% confidence interval: -13.2% to -7.7%, P < 0.001 for non-inferiority, P < 0.001 for superiority). The mean absolute difference between final cardiologist assessment and independent previous cardiologist assessment was 6.29% in the AI group and 7.23% in the sonographer group (difference of -0.96%, 95% confidence interval: -1.34% to -0.54%, P < 0.001 for superiority). The AI-guided workflow saved time for both sonographers and cardiologists, and cardiologists were not able to distinguish between the initial assessments by AI versus the sonographer (blinding index of 0.088). For patients undergoing echocardiographic quantification of cardiac function, initial assessment of LVEF by AI was non-inferior to assessment by sonographers.
More Related Videos
05:04Author Spotlight: Evaluating Clinicians' Adoption of Ultrasound-Guided Vascular Cannulation Through Simulation Training
Published on: August 9, 2024
11:27A Modified Sonographic Algorithm for Image Acquisition in Life-Threatening Emergencies in the Critically Ill Newborn
Published on: April 7, 2023
Related Concept Videos
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Imaging Studies II: Ultrasonography
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: