Related Experiment Video
Updated: Aug 4, 2025

Optical Coherence Tomography Based Biomechanical Fluid-Structure Interaction Analysis of Coronary Atherosclerosis Progression
Published on: January 15, 2022
Prediction of the debulking effect of rotational atherectomy using optical frequency domain imaging: a prospective
Tomoyo Hamana1, Hiroyuki Kawamori1, Takayoshi Toba1
1Division of Cardiovascular Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-Cho, Chuo-Ku, Kobe, Hyogo, 650-0017, Japan.
Abstract:
This study determined the predictive accuracy of optical frequency domain imaging (OFDI) on debulking effects of rotational atherectomy (RA) and compared the predictive accuracy of OFDI catheter-based with Rota wire-based prediction methods. This prospective, single-center, observational study included 55 consecutive patients who underwent OFDI-guided RA. On pre-RA OFDI images, a circle, identical to the Rota burr was drawn at the center of the OFDI catheter (OFDI catheter-based prediction method) or wire (wire-based prediction method). The area overlapping the vessel wall was defined as the predicted ablation area (P-area). The actual ablated area (A-area) was measured by superimposing the OFDI images before and after RA. The overlapping P-area and A-area were defined as overlapped ablation area (O-area), and the predictive accuracy was evaluated by %Correct area (O-area/P-area) and %Error area (A-area - O-area/A-area). The median %Correct and %Error areas were 47.8% and 41.6%, respectively. Irrelevant ablation (low %Correct-/high % Error areas) and over ablation (high %Correct-/high % Error areas) were related to deep vessel injury and intimal flap outside the P-area. The predictive accuracy was better in the OFDI catheter-based prediction method than the wire-based prediction method in the cross sections where the OFDI catheter and wire came in contact. However, it was better in the latter than the former where the OFDI catheter and wire were not in contact. OFDI-based simulation of the RA effect is feasible though accuracy may be affected by the OFDI catheter and wire position. OFDI-based simulation of RA effect might reduce peri-procedural complications during RA.
More Related Videos
11:45Generation and 3-Dimensional Quantitation of Arterial Lesions in Mice Using Optical Projection Tomography
Published on: May 26, 2015
14:21Optical Frequency Domain Imaging of Ex vivo Pulmonary Resection Specimens: Obtaining One to One Image to Histopathology Correlation
Published on: January 22, 2013