Related Experiment Video
Updated: Aug 4, 2025

Experimental Investigation of the Hierarchical Control in DC Microgrids Using a Real-time Simulator
Published on: February 14, 2025
An On-/Off-Time Sensing-Based Load-Adaptive Mode Control of Triple Mode Buck Converter for Implantable Medical
Abstract:
Wireless power transfer (WPT) technology applied to implantable medical devices (IMDs) significantly reduces the need for battery replacement surgery health conditions. This paper presents an on-/off-time sensing-based load-adaptive mode control of triple mode buck converter for implantable medical devices; the converter can adjust the control mode for low power consumption and achieve high power conversion efficiency (PCE) under a small active area. The three modes in the proposed system are the pulse width modulation (PWM), pulse frequency modulation (PFM), and ultra-low power (ULP) modes. The on-time sensor can be used to adjust the system from PWM to PFM modes, and the off-time sensor can be used to adjust the system from PFM to ULP modes. It is fabricated using TSMC 0.18 µm CMOS technology. The input voltage lies in the range 2.2-5.0 V, the output voltage is 1.8 V, and the load current lies in the range 0.05-200 mA (x4000). The experimental results demonstrate the seamless mode transition under the step up/down load transient response. The peak PCE is approximately 94.3% at the 80 mA and the minimum PCE is approximately 65.4% within the load current range.
Related Concept Videos
MOSFET: Enhancement Mode
In their basic form, enhancement-mode MOSFETs are typically non-conductive when the gate-source voltage (Vgs) is zero. This default 'off' state means no...
Modes of Operations of BJT
Active Mode: The most common mode for amplification, the active mode features a forward-biased emitter-base junction and a reverse-biased base-collector junction. This setup enables electrons to be injected from the emitter to the base while blocking the majority carriers at the collector. The...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
MOSFET: Depletion Mode
The primary characteristic of depletion-mode MOSFETs is their ability to conduct current between the drain and source terminals without gate bias. This inherent conductivity...
Bipolar Junction Transistor
Mitral Stenosis III: Medical Management

