Related Experiment Video
Updated: Aug 4, 2025

A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Assessment of 18F-DCFPyL PSMA PET/CT and PET/MR quantitative parameters for reference standard organs: Inter-reader,
Edward M Lawrence1, Minnie Kieler1, Greg Cooley2
1Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin, United States of America.
Prostate specific membrane antigen (PSMA)-based [18F]DCFPyL (PyL) PET imaging shows reliable quantitative reference standards in the liver, blood pool, and whole parotid gland for prostate cancer assessment. Smaller parotid gland regions of interest may introduce variability.
Area of Science:
- Nuclear Medicine
- Radiochemistry
- Oncology
Background:
- Prostate specific membrane antigen (PSMA)-based radiotracers are crucial for prostate cancer assessment.
- Quantitative variability and reference standards are essential for clinical and research applications of PSMA PET imaging.
- This study focuses on evaluating the quantitative variability of PSMA-based [18F]DCFPyL (PyL) PET quantitative reference standards.
Purpose of the Study:
- To assess the quantitative variability of PSMA-based [18F]DCFPyL (PyL) PET quantitative reference standards.
- To determine the reliability of liver, blood pool, and parotid gland as reference normal organs for PET imaging.
- To compare quantitative measurements between whole-body PET/CT and whole-body PET/MR.
Main Methods:
- Consecutive patients with biochemically recurrent prostate cancer underwent whole-body PET/CT followed by whole-body PET/MR after PyL injection.
- Two independent readers defined regions of interest (ROIs) in the parotid gland (whole gland and 1-cm spheres), liver, and blood pool.
- Bland-Altman analysis, interquartile range (IQR), and coefficient of variance (CoV) were used to evaluate inter-reader and inter-subject variability.
Main Results:
- Minimal inter-reader variability was observed for SUVmean in the blood pool, liver, and whole parotid gland for both PET/CT and PET/MR.
- Greater inter-reader variability was noted for 1-cm parotid gland ROIs.
- Comparing PET/CT to PET/MR, blood pool SUVmean slightly decreased, while liver and parotid gland SUVmean slightly increased, with absolute bias ranging from 0.45-1.28.
- Inter-subject variability was higher in the parotid gland compared to liver and blood pool.
Conclusions:
- Liver, blood pool, and whole parotid gland quantitation demonstrate promise as reliable reference normal organs for clinical and research PET applications.
- The use of smaller parotid gland ROIs (1-cm spheres) may introduce significant variability, potentially limiting their utility.
- PSMA-based [18F]DCFPyL (PyL) PET offers valuable quantitative data for prostate cancer assessment when appropriate reference standards are employed.
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...

