Simultaneous spatial and temporal regularization in low-dose dynamic contrast-enhanced CT cerebral perfusion studies.
Kenya Murase1, Atsushi Nakamoto1, Noriyuki Tomiyama2
1Department of Future Diagnostic Radiology, Graduate School of Medicine, Osaka University, Suita, Osaka, Japan.
Total Generalized Variation (TGV) and its combination with low-rank and sparse decomposition (LTGV) improve accuracy in low-dose dynamic contrast-enhanced CT perfusion studies. These methods offer better image quality and parameter estimation than Total Variation (TV) based approaches.
Area of Science:
- Medical Imaging
- Radiology
- Computational Imaging
Background:
- Low-dose dynamic contrast-enhanced computed tomography (DCE-CT) is crucial for cerebral perfusion studies.
- Image reconstruction in low-dose DCE-CT requires effective regularization techniques to mitigate noise and artifacts.
- Traditional methods like Total Variation (TV) have limitations in preserving fine details and accuracy.
Purpose of the Study:
- To evaluate the performance of Total Generalized Variation (TGV) and its combination with low-rank and sparse decomposition (LTGV) for low-dose DCE-CT cerebral perfusion imaging.
- To compare TGV and LTGV against Total Variation (TV) and its combination with low-rank and sparse decomposition (LTV), as well as reconstructions without regularization.
- To quantitatively assess the impact of these regularizers on image quality and cerebral perfusion parameter (CPP) estimation accuracy using simulation and clinical data.
Main Methods:
- Simulation study using a digital brain phantom with low-dose DCE-CT image reconstruction.
- Generation of cerebral perfusion parameter (CPP) images from reconstructed DCE-CT data.
- Quantitative evaluation using Peak Signal-to-Noise Ratio (PSNR), Structural Similarity Index Measure (SSIM), linear regression analysis for CPP accuracy, and region analysis.
Main Results:
- LTV and LTGV demonstrated higher PSNR and SSIM values compared to other methods, particularly with increased regularization parameters.
- TGV generally showed the best performance in accuracy, followed by LTGV, with TV significantly differing from the other regularizers.
- Simulation and clinical results showed overall consistency, although some discrepancies arose from differences in low-dose image generation.
Conclusions:
- TGV and LTGV are effective regularizers for enhancing the accuracy of cerebral perfusion parameter estimation in low-dose DCE-CT.
- The study provides valuable insights into the performance of different regularizers, aiding in the selection of optimal methods for low-dose DCE-CT perfusion studies.
- These findings support the potential for improved diagnostic capabilities in cerebral perfusion imaging with reduced radiation exposure.