Readout-segmented diffusion weighted imaging of the testis at 3.0 T: comparison with single-shot echo-planar imaging
Feifei Yao1, Mengyue Huang2, Juan Li2
1Department of MRI, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, 450052, China. yaofeifei0501@163.com.
Objective:
The current study aimed to explore the feasibility of readout-segmented echo-planar imaging (RS-EPI) of the testis at 3.0 T, by comparing with single-shot echo-planar imaging (SS-EPI) in qualitative image quality and quantitative apparent diffusion coefficient (ADC) values.
Methods:
66 patients undergoing scrotal MRI for various clinical indications were included retrospectively. RS-EPI image quality was rated from 1 (severe distortion or artifact, or nondiagnostic) to 4 (nearly no distortion or artifact, or outstanding). The comparative image quality (RS- vs. SS-EPI) was rated from - 2 (SS-EPI severe or greater conspicuity) to 2 (RS-EPI severe or greater conspicuity). The confidence interval of proportions (CIOP) of comparative image quality and Wilcoxon rank sum test were performed to assess the preferences between RS-EPI and SS-EPI. Paired samples t-test and Bland-Altman analysis were performed to compare the mean ADC values of RS-EPI and SS-EPI. The mean, maximum, and minimum ADC values measured by RS-EPI were compared in normal testicular parenchyma, benign and malignant intratesticular lesions.
Results:
The evaluation of RS-EPI image quality showed RS-EPI with the characteristics of slight geometric distortion and susceptibility artifact, and good lesion conspicuity. The assessment of comparative image quality showed SS-EPI with obvious geometric distortion and susceptibility artifact, and RS-EPI preferred in lesion conspicuity. The CIOP ranged from 97 to 100% among three readers, with preferring to RS-EPI improving image quality (P < 0.001). There was a strong correlation and good agreement between mean ADC values measured by RS-EPI and SS-EPI. The mean, maximum and minimum ADC values by RS-EPI were significantly different in normal testicular parenchyma, benign and malignant intratesticular lesions.
Conclusion:
RS-EPI DWI of the testis improved image quality in geometric distortion, susceptibility artifacts, and lesion conspicuity, and provided highly correlated and consistent mean ADC values when compared to SS-EPI DWI, indicating the feasibility of RS-EPI DWI of testes.
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Imaging Studies III: Computed Tomography
Imaging Studies II: Ultrasonography
Imaging Studies IV: Magnetic Resonance Imaging
Magnetic Resonance Imaging
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET