Related Experiment Video
Updated: Aug 3, 2025

Novel and Innovative Hybrid Technique for Type A Aortic Dissection
Published on: March 28, 2025
Conduction Disorders And Their Clinical Impact After Sutureless/Rapid Deployment Aortic Bioprosthesis
Ricardo Ferreira1, Marta Figueiral2, André Sena1
1Cardiothoracic Surgery Department, Santa Maria Hospital, Lisbon, Portugal.
Insights
Rapid deployment valves (RDV) for aortic stenosis may increase the need for permanent pacemakers (PPM). PPM implantation is linked to higher stroke risk and longer hospital stays, especially with pre-existing conduction issues.
Area of Science:
- Cardiovascular Surgery
- Interventional Cardiology
- Medical Devices
Background:
- Aortic stenosis is a leading heart valve pathology.
- Rapid deployment valves (RDV) aim to reduce surgical times.
- Concerns exist regarding increased conduction abnormalities and permanent pacemaker (PPM) implantation with RDVs.
Purpose of the Study:
- To investigate the incidence of conduction abnormalities after aortic valve replacement using RDVs.
- To assess the impact of PPM implantation on immediate postoperative outcomes.
Main Methods:
- Retrospective analysis of 201 patients undergoing isolated aortic valve replacement with RDV (April 2014 - December 2019).
- Evaluation of conduction disorders, PPM rates, and postoperative outcomes.
- Comparative analysis between PPM and non-PPM groups, excluding specific patient subgroups.
Main Results:
- Left bundle branch block was the most common abnormality (54.0%).
- PPM implantation occurred in 12.6% of patients.
- The PPM group had higher rates of stroke (7.7%) and prolonged hemodynamic support (60.0%). Preoperative right bundle branch block was an independent risk factor for PPM.
Conclusions:
- High PPM implantation rates with RDVs are associated with prolonged hospital stays, ICU stays, and increased stroke risk.
- RDV use requires careful consideration of preoperative conduction status, particularly right bundle branch block.
- Case-by-case decision-making is recommended for RDV implantation.
Introduction:
Aortic stenosis remains the number one heart valve pathology. The drive to improve the surgical outcomes brought to focus rapid deployment valves (RDV), which reduce aortic cross-clamping and cardio-pulmonary bypass (CPB) times. However, some centers have reported a higher rate of conduction abnormalities and permanent pacemaker (PPM) implantation. The aim of this study was to investigate the incidence of conduction abnormalities after aortic valve replacement with RDV, as well as its impact on immediate postoperative outcomes.
Methods:
Retrospective analysis of associated conductions disorders and PPM implantation rates, as well as post-operative outcomes of all patients undergoing isolated aortic valve replacement between April 2014 and December 2019 with an RDV. Comparative analysis between the group with PPM implantation and the one with no PPM implantation. Patients with previous PPM implantation, reoperations and patients with missing pre or postoperative ECG data were excluded.
Results:
We studied 201 patients. The majority of conduction abnormalities were left bundle branch block (54,0%). Twenty-six PPM were implanted (12,6%). Pre-operative characteristic between the groups were similar and little differences were found in regard to most complications. However, the PPM group showed significantly higher rates of stroke (7.7% vs 0.0%, p=0.016) and hemodynamic support for longer than 24 hours (60.0% vs 36.1%, p=0.028). From the multivariable analysis, preoperative right bundle branch block was the only independent risk factor associated with PPM.
Conclusions:
PPM implantation rates with RDV are relatively high and are associated with prolonged hospital and ICU stays, postoperative stroke rates and requirement of aminergic support. Their use should be made on a case-by-case basis taking into consideration the existence of preoperative conduction disorders, especially right bundle branch block.
More Related Videos
07:02Operating Transverse Aortic Constriction with Absorbable Suture to Obtain Transient Myocardial Hypertrophy
Published on: September 9, 2020
06:51Author Spotlight: Development of a Minimally Invasive Large-Animal Model for Reliable and Reproducible Cardiovascular Research
Published on: October 20, 2023
Related Concept Videos
Aneurysm III: Interprofessional Care
Aortic Regurgitation I: Introduction
Aneurysm IV: Nursing Management