Investigating analyte breakthrough under non-linear isotherm conditions during solid phase extraction facilitated by
Grant S Ochoa1, Robert E Synovec1
1Department of Chemistry, University of Washington, Seattle, Box 351700, WA, 98195, USA.
Abstract:
Solid phase extraction (SPE) sample preparation for the analysis of complex organic mixtures is often applied assuming all analytes of interest will preconcentrate on the stationary phase. This assumption ignores the reality that extraction is a dynamic interactive process and a diverse range of affinities for the stationary phase will result in equally diverse breakthrough volumes due to competitive sorption processes. To study this dynamic interactive process, and further to take advantage of it, we extracted a JP-8 jet fuel spiked with 40 ppm of a polar compound mix with silica and alumina SPE cartridges and analyzed sequential extracted fractions of the fuel to both assess the shifting chemical landscape present in the extraction and the impact of both SPE stationary phases on this process. Tile-based 1v1 comparative analysis (a recently reported extension of tile-based Fisher ratio analysis) was used to discover the (polar) compounds whose concentrations change between extracted fractions, discovering 21 compounds extracted with silica and 27 compounds extracted with alumina with at least a 2-fold change in concentration from the neat sample relative to the first 1 mL pass fraction sample. These compounds were quantified in each fraction to construct concentration ratio profiles, defined as the concentration ratio for a given SPE fraction per analyte compound relative to the analyte concentration in the neat fuel, for which the extraction behavior for each analyte could be assessed. These analyte compounds were found to breakthrough at different rates, with some analytes remaining on the column indefinitely (until extracted with a subsequent polar solvent) and other analytes eluting before the extraction is complete. Furthermore, in a comparison of the effect of selected stationary phase, alumina was found to retain oxygen-containing phenolic compounds to a greater extent than silica. Principal component analysis (PCA) was used to analyze the concentration ratio profiles of the various trace analytes in the JP8 fuel (phenols, indoles, etc.) in the context of their stationary phase affinity (silica or alumina) and competitive sorption behavior.
More Related Videos
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
10:14Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Tandem Mass Spectrometry
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences