A Case of Unintentional Release of the Watchman FLX Device During Implantation: A Cautionary Tale
Ajoe J Kattoor1, Christopher Manion1, Chee H Kim2
1Interventional and Structural Cardiology, Kaleida Health/University at Buffalo, Buffalo, USA.
Insights
A case report details a Watchman FLX device dislodgement during left atrial appendage closure in an atrial fibrillation patient. The device self-deployed successfully, highlighting procedural technique importance.
Area of Science:
- Cardiology
- Medical Devices
- Interventional Cardiology
Background:
- Atrial fibrillation (AF) increases stroke risk.
- The Watchman FLX device offers percutaneous left atrial appendage closure for AF patients.
- Device dislodgement is a potential complication during Watchman FLX procedures.
Abstract:
Atrial fibrillation (AF) is a common heart rhythm disorder that increases the risk of stroke and other cardiovascular complications. The Watchman FLX device is a percutaneous device used for the closure of the left atrial appendage in patients with atrial fibrillation and prevents blood clots from forming, thereby decreasing the risk of stroke. However, device dislodgement during the procedure can occur and compromise the effectiveness of the device. In this case report, we present the experience of an 86-year-old man with a history of atrial fibrillation, coronary artery disease, hypertension, and recent gastrointestinal bleeding due to diverticulosis. During the procedure, the device became dislodged prior to the planned release from the shaft due to the difficult anatomy of the appendage, which caused the operator to over-torque and kink the delivery sheath. The kinked sheath prevented the transmission of torque to the appropriate region of the sheath and caused the device to unscrew prematurely. Fortunately, the device was self-deployed in a satisfactory position, and no further intervention was required. The patient did not experience any complications prior to discharge and follow-up echocardiography showed proper positioning of the device. This case highlights the importance of careful technique during the Watchman FLX procedure and the need to replace the delivery sheath if kinking is noted to prevent unintentional dislodgement of the device. In addition, the case was written with the aid of the artificial intelligence-powered language model ChatGPT and demonstrates its benefits as well as calls for caution while using it for medical writing.
More Related Videos
16:40A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
28:13Catheter Ablation in Combination With Left Atrial Appendage Closure for Atrial Fibrillation
Published on: February 26, 2013
Related Concept Videos
Bacterial Signaling
Holter Monitor: 24-Hour Monitoring