Future lines of research on phase angle: Strengths and limitations

Diego Bellido1, Cristina García-García2, Antonio Talluri3

  • 1Department of Endocrinology and Nutrition, Complejo Hospitalario de Ferrol, 15405, Ferrol, A Coruña, Spain.

Related Concept Videos

Time and frequency -Domain Interpretation of Phase-lead Control01:24

Time and frequency -Domain Interpretation of Phase-lead Control

Phase-lead controllers are commonly used in various control systems to enhance response speed and stability. Adjusting the brightness on a television screen offers a practical example of phase-lead control. When contrast is enhanced, a phase-lead controller is employed. Mathematically, phase-lead control is identified when the first parameter is smaller than the second.
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
117
Fault Types01:18

Fault Types

When analyzing a single line-to-ground fault from phase A to ground at a three-phase bus, it is important to consider the fault impedance. This impedance is zero for a bolted fault, equal to the arc impedance for an arcing fault, and represents the total fault impedance for a transmission-line insulator flashover. To derive sequence and phase currents, fault conditions are translated from the phase domain to the sequence domain.
For line-to-line faults occurring between phases B and C, the...
111
Time and frequency -Domain Interpretation of Phase-lag Control01:21

Time and frequency -Domain Interpretation of Phase-lag Control

Phase-lag controllers are widely used in control systems to improve stability and reduce steady-state errors. A dimmer switch controlling the brightness of a light bulb serves as a practical example of phase-lag control, gradually adjusting the bulb's brightness. Mathematically, phase-lag control or low-pass filtering is represented when the factor 'a' is less than 1.
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any...
130
Phasor Arithmetics01:13

Phasor Arithmetics

Phasors and their corresponding sinusoids are interrelated, offering unique insights into the behavior of alternating current (AC) circuits. One way to understand this relationship is through the operations of differentiation and integration in both the time and phasor domains.
When the derivative of a sinusoid is taken in the time domain, it transforms into its corresponding phasor multiplied by j-omega (jω) in the phasor domain, where j is the imaginary unit, and ω is the angular...
342
Phase-lead and Phase-lag Controllers01:22

Phase-lead and Phase-lag Controllers

Understanding the working function of different types of controllers can be illustrated with practical analogies, such as adjusting a stereo's volume equalizer. Cranking up the bass involves a phase-lead controller, which functions as a high-pass filter, while increasing the treble uses a phase-lag controller, which acts as a low-pass filter. PD controllers, similar to high-pass filters, enhance the system's response to high-frequency components. PI controllers, akin to low-pass...
208
Phasors01:12

Phasors

Phasors are a powerful mathematical tool used to analyze alternating current (AC) circuits. They provide a complex number representation of sinusoids, with the magnitude of the phasor equating to the amplitude of the sinusoid and the angle of the phasor representing the phase measured from the positive x-axis.
One of the significant benefits of using phasors is that they simplify the analysis of AC circuits by eliminating the time dependence of the current and voltage. This transformation...
606