A GATE Monte Carlo framework for dosimetric evaluation in mammography in an Algerian hospital
Billel Abdelaziz Bouchikhi1, Saadia Benhalouche1, Moncef Ati2
1Laboratoire d'Analyse et d'Application des Rayonnements (LAAR), Département de Génie physique, Université des Sciences et de la Technologie d'Oran, Mohamed Boudiaf USTO-MB, El Mnaouar, BP 1505, Bir El Djir, 31000, Oran, Algeria.
Abstract:
A framework has been developed for dosimetric evaluation in mammography, using the GATE Monte Carlo (MC) platform, to simulate a MAMMOMAT 3000 Nova mammograph (Siemens) available at the University Hospital Center "1st November 1954" of Oran (EHU Oran 1er Novembre, 1954), Algeria. Calculated quantities such half-value layer (HVL), Entrance Surface Dose (ESD) and Mean Glandular Dose (MGD) have been compared to experimental data in order to validate the modeling of mammography examinations. Results are consistent with previous studies and show a good agreement between measurements and Monte Carlo calculations. By varying the tube voltage from 25 to 35 kV, we have estimated an increasing of a factor of 2.4 in ESD, and a factor of 2.75 for the MGD in a breast phantom. Furthermore, the current intensity of 100 mAs used for a beam quality combination (Mo/Mo) Anode/filter was found suitable for the tube voltages of 25-29 keV since the MGD does not exceed the limits set by the different quality insurance protocols. This GATE dose calculation framework thus provides a very useful tool for the optimization of mammography examinations at Oran hospital by allowing a better estimation of the dose delivered to patients according to the parameters of the examination.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...