To investigate the diagnostic feasibility of a shortened breast PET/MRI protocol in breast cancer patients.
Methods:
Altogether 90 women with newly diagnosed T1tumor-staged (T1ts) and T2tumor-staged (T2ts) breast cancer were included in this retrospective study. All underwent a dedicated comprehensive breast [18F]FDG-PET/MRI. List-mode PET data were retrospectively reconstructed with 20, 15, 10, and 5 min for each patient to simulate the effect of reduced PET acquisition times. The SUVmax/mean of all malign breast lesions was measured. Furthermore, breast PET data reconstructions were analyzed regarding image quality, lesion detectability, signal-to-noise ratio (SNR), and image noise (IN). The simultaneously acquired comprehensive MRI protocol was then shortened by retrospectively removing sequences from the protocol. Differences in malignant breast lesion detectability between the original and the fast breast MRI protocol were evaluated lesion-based. The 20-min PET reconstructions and the original MRI protocol served as reference.
Results:
In all PET reconstructions, 127 congruent breast lesions could be detected. Group comparison and T1ts vs. T2ts subgroup comparison revealed no significant difference of subjective image quality between 20, 15, 10, and 5 min acquisition times. SNR of qualitative image evaluation revealed no significant difference between different PET acquisition times. A slight but significant increase of IN with decreasing PET acquisition times could be detected. Lesion SUVmax group comparison between all PET acquisition times revealed no significant differences. Lesion-based evaluation revealed no significant difference in breast lesion detectability between original and fast breast MRI protocols.
Conclusions:
Breast [18F]FDG-PET/MRI protocols can be shortened from 20 to below 10 min without losing essential diagnostic information.
Key Points:
• A highly accurate breast cancer evaluation is possible by the shortened breast [18F]FDG-PET/MRI examination protocol. • Significant time saving at breast [18F]FDG-PET/MRI protocol could increase patient satisfaction and patient throughput for breast cancer patients at PET/MRI.
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies IV: Magnetic Resonance Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Magnetic Resonance Imaging
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET