Influence of contrast agent on artificial intelligence-based CT low attenuation volume percentage measurement
Damian Wiedbrauck1,2, Maciej Karczewski3, Stefan O Schoenberg2
1Department of Radiology, AKH Celle, Celle, Germany.
Background:
Low attenuation volume percentage (LAV%) has been identified as a quantitative imaging biomarker for emphysema with good correlation with spirometry. The influence of intravenous contrast agent on LAV% and its correlation with spirometry is not well known.
Purpose:
To evaluate the influence of intravenous contrast agent on artificial intelligence (AI)-based LAV% in correlation with spirometric Tiffeneau-Pinelli Index (TI).
Material And Methods:
In a retrospective study, two groups of 47 patients (mean age 68.04 ± 12.64 and 67.89 ± 11.54 years) with either non-enhanced chest computed tomography (CT) or contrast-enhanced CT were compared. Using an AI-based software, LAV% was quantified using a threshold <-950 HU. TI was calculated from spirometry and pathologic airway obstruction was considered with a TI <70. The effect of contrast agent on LAV% and the relationship between TI and LAV% was analyzed. Correlation coefficients between TI and LAV% were compared for both groups.
Results:
Patients with non-enhanced CT had a mean LAV% of 9.07 ± 7.53. Of them, 22 patients had a TI <70% and 25 patients a TI ≥70%. Patients with contrast-enhanced CT had a mean LAV% of 6.54 ± 4.62. Of them, 20 patients had a TI <70% and 27 patients had a TI ≥70%. Contrast agent did not show a major effect on LAV% (P = 0.099) and the relationship between TI and LAV% (P = 0.88). In both groups, a significant correlation between TI and LAV% was found (ρ = -0.317 for non-enhanced CT; ρ = -0.514 for contrast-enhanced CT). Difference between correlation coefficients was insignificant.
Conclusion:
Our findings suggest that contrast agent does not influence LAV% nor its correlation with TI.
More Related Videos
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...