Related Experiment Video
Updated: Aug 3, 2025

The Supraclavicular Fossa Ultrasound View for Central Venous Catheter Placement and Catheter Change Over Guidewire
Published on: December 23, 2014
Fluoroscopically guided repositioning of peripherally inserted central catheter in patients failing
Zi-Xuan Wang1, Lin Li1, Yi-Fan Zhao1
1Department of Interventional Radiology, Qingdao Hospital, University of Health and Rehabilitation Sciences (Qingdao Municipal Hospital), Qingdao, PR China.
Background:
Ultrasound (US)-guided-only insertion at the bedside is safe and improves the success rates of peripherally inserted central catheter (PICC). However, PICC insertion procedures remain challenging for special cases.
Purpose:
To show that fluoroscopically guided tip repositioning, for failed US-guided PICC placement, safely led to satisfactory positioning in difficult cases and, importantly, improved success rates of PICC placements.
Material And Methods:
A retrospective study of 1560 patients who underwent US-guided PICC placement were performed. Patients who failed US-guided PICC placement were transferred to the interventional radiology department for fluoroscopically guided tip repositioning. Baseline characteristics as well as insertion-related factors were collected. All data were analyzed using SPSS software.
Results:
In total, 37 (2.4%) patients who failed US-guided PICC placement accepted fluoroscopically guided adjustment or re-insertion. Of these 37 patients, 32 were enrolled. We observed no significant differences between right and left arm PICC access (P > 0.05), even though a higher percentage of PICCs were inserted into left arms (56.3%). The basilic vein (65.6%) was the most common insertion site. Only four patients experienced slight angiospasm (3.1%) and venous thrombosis (9.4%). US-guided PICC insertion failures were primarily due to line tip malposition (84.4%). All patients successfully underwent fluoroscopically guided tip repositioning, which resulted in optimal catheter tip positioning. PICC lines were adjusted in most patients (n=28, 87.5%).
Conclusion:
Malposition was the primary issue causing US-guided PICC insertion failure. Fluoroscopically guided tip repositioning safely and efficaciously led to satisfactory positioning in difficult cases; thus, we recommend this method for patients failing US-guided PICC placement.
More Related Videos
Related Concept Videos
Parentral Nutrition: Centeral and Peripheral Parental Nutrition
PN can be administered through two primary routes:
1. Central Parenteral Nutrition (CPN):
CPN involves delivering a high concentration of nutrients through a large vein. This is typically achieved using a Peripherally Inserted Central Catheter (PICC) or,...
Cardiac Catheterization III: Left Heart Catheterization
Cardiac Catheterization IV: Nursing Management
Cardiac Catheterization I: Pre-Procedure Overview
Cardiac Catheterization II: Right Heart Catheterization
Imaging Studies VII: Vascular Imaging