Related Experiment Video
Updated: Aug 3, 2025

Improvement of a Closed Chest Porcine Myocardial Infarction Model by Standardization of Tissue and Blood Sampling Procedures
Published on: March 12, 2018
Cardiac Troponin I in Patients Undergoing Percutaneous and Surgical Myocardial Revascularization: Comparison of
Sabrina Pacheco do Amaral Vendramini1, Célia Maria Cássaro Strunz1, Whady Armindo Hueb2
1Laboratorio de Analises Clinicas, Instituto do Coracao (InCor), Hospital das Clinicas HCFMUSP, Faculdade de Medicina, Universidade de Sao Paulo, Sao Paulo 05403-900, SP, Brazil.
Abstract:
The myocardial infarction (MI) types 4a and 5 guidelines recommend cardiac troponin (cTn) diagnostic decision limits of 5 and 10 times the 99th percentile, respectively. Different cTn kits elicit different responses, so the MI diagnosis is still challenging. The study aimed to establish the cutoff values and the accuracy of three different cTnI kits in the diagnosis of post-procedural MI. We analyzed 115 patients with multivessel stable chronic coronary artery disease; 26 underwent percutaneous coronary intervention, and 89 underwent coronary artery bypass graft. Delayed-enhancement magnetic resonance imaging was performed before and after each intervention for definitive MI diagnoses. Two contemporary and one high-sensitivity cTnI immunoassays were used. ROC curves determined the accuracy of each assay. Low accuracy was observed after applying the current guidelines recommendations. The three cTnI assays accuracies improved when adjusted by the new ROC cutoffs, reaching 82% for MI type 5 for all assays, and 78%, 88%, and 87% for MI type 4 for Siemens, Beckman, and Abbott, respectively. The ultrasensitive and contemporary tests' accuracy for MI types 4a and 5 diagnoses are equivalent when adjusted for these new cutoffs. The hs-cTnI assays had lower accuracy than contemporary tests for MI types 4a and 5 diagnoses.
More Related Videos
10:12A Sensitive and Specific Quantitation Method for Determination of Serum Cardiac Myosin Binding Protein-C by Electrochemiluminescence Immunoassay
Published on: August 8, 2013
07:31A Model of Cardiac Remodeling Through Constriction of the Abdominal Aorta in Rats
Published on: December 2, 2016
Related Concept Videos
Blood Studies for Cardiovascular System I: Cardiac Biomarkers
The essential diagnostic tools for detecting myocardial necrosis and monitoring individuals suspected of having acute coronary syndrome (ACS) include:
Troponins
Troponins, particularly cardiac troponins I and T, are the most precise and sensitive markers of myocardial injury. They are detectable within 4-6 hours of myocardial injury and remain...
Acute Coronary Syndrome III: Diagnostic Studies
Cardiac Catheterization I: Pre-Procedure Overview
Acute Coronary Syndrome I: Introduction
Imaging Studies for Cardiovascular System V: CT
Myocarditis II: Clinical Features and Diagnostic Tests