Related Experiment Video
Updated: Aug 3, 2025

08:34
Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
20.4K
Rotating Gantries Provide Individualized Beam Arrangements for Charged Particle Therapy.
Siven Chinniah1, Amanda J Deisher2, Michael G Herman2
1Mayo Clinic Alix School of Medicine, Jacksonville, FL 32224, USA.
Cancers
|April 13, 2023
Summary
Highly individualized proton therapy plans for carbon ion radiotherapy-eligible patients utilize a wide range of beam angles. A rotating gantry is optimal for achieving diverse beam arrangements in proton therapy.
Area of Science:
- Medical Physics
- Radiation Oncology
- Radiotherapy Technology
Background:
- Carbon ion radiotherapy (CIRT) offers potential advantages for specific cancers.
- Proton therapy planning requires precise beam angle selection for optimal dose delivery.
- Individualized treatment plans are crucial for maximizing tumor coverage and minimizing dose to healthy tissues.
Purpose of the Study:
- To evaluate the distribution and utilization of beam angles in proton therapy for patients eligible for CIRT.
- To determine if specific beam angle arrangements are favored across different anatomical sites.
Main Methods:
- Retrospective analysis of 467 patients treated with pencil beam scanning intensity modulated proton therapy (2015-2020).
- Evaluation of treatment plans generated using a 190° rotating gantry and robotic patient positioning.
- Grouping and histogram analysis of utilized beam angles by anatomical treatment site.
Main Results:
- A total of 484 plans and 1196 unique beam angles were analyzed.
- The most frequently used beam angles were 0° and 180°.
- Most anatomical sites demonstrated a wide distribution of beam angles, except for esophageal cancers (unimodal) and pancreas cancers (modest grouping).
Conclusions:
- The extensive use of diverse beam angles supports the efficacy of a rotating gantry system.
- A rotating gantry facilitates highly individualized beam arrangements for CIRT-eligible patients.
- Proton therapy planning benefits from a wide range of beam angle options for complex cases.
Related Concept Videos
Motion Of A Charged Particle In A Magnetic Field
5.0K
A charged particle experiences a force when moving through a magnetic field. Consider the field to be uniform and the charged particle to move perpendicular to it. If the field is in a vacuum, the magnetic field is the dominant factor determining the motion. Since the magnetic force is perpendicular to the direction of motion, a charged particle follows a curved path. The particle continues to follow this curved path until it forms a complete circle. Another way to look at this is that the...
5.0K
Van de Graaff Generator
1.8K
Van de Graaff generators (or Van de Graaffs) are devices used to demonstrate high voltage due to static electricity that can also be used for research. Robert Van de Graaff first built one in 1931 (based on original suggestions by Lord Kelvin) for use in nuclear physics research.
Van de Graaff uses both smooth and pointed surfaces, conductors, and insulators to generate large static charges and, hence, large voltages. A substantial excess charge can be deposited on the sphere because it moves...
Van de Graaff uses both smooth and pointed surfaces, conductors, and insulators to generate large static charges and, hence, large voltages. A substantial excess charge can be deposited on the sphere because it moves...
1.8K